Vulnerabilities > Schneider Electric
DATE | CVE | VULNERABILITY TITLE | RISK |
---|---|---|---|
2021-07-21 | CVE-2021-22777 | Unspecified vulnerability in Schneider-Electric Sosafe Configurable A CWE-502: Deserialization of Untrusted Data vulnerability exists that could cause code execution by opening a malicious project file. | 7.8 |
2021-07-21 | CVE-2021-22784 | Unspecified vulnerability in Schneider-Electric C-Bus Toolkit 1.15.7/1.15.8 A CWE-306: Missing Authentication for Critical Function vulnerability exists in C-Bus Toolkit v1.15.8 and prior that could allow an attacker to use a crafted webpage to obtain remote access to the system. | 5.7 |
2021-07-14 | CVE-2021-22778 | Unspecified vulnerability in Schneider-Electric products Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause protected derived function blocks to be read or modified by unauthorized users when accessing a project file. | 7.1 |
2021-07-14 | CVE-2021-22779 | Unspecified vulnerability in Schneider-Electric products Authentication Bypass by Spoofing vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (all versions), Modicon M580 CPU (all versions - part numbers BMEP* and BMEH*), Modicon M340 CPU (all versions - part numbers BMXP34*), that could cause unauthorized access in read and write mode to the controller by spoofing the Modbus communication between the engineering software and the controller. | 9.1 |
2021-07-14 | CVE-2021-22780 | Unspecified vulnerability in Schneider-Electric products Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause unauthorized access to a project file protected by a password when this file is shared with untrusted sources. | 7.1 |
2021-07-14 | CVE-2021-22781 | Insufficiently Protected Credentials vulnerability in Schneider-Electric products Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause a leak of SMTP credential used for mailbox authentication when an attacker can access a project file. | 5.5 |
2021-07-14 | CVE-2021-22782 | Unspecified vulnerability in Schneider-Electric products Missing Encryption of Sensitive Data vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause an information leak allowing disclosure of network and process information, credentials or intellectual property when an attacker can access a project file. | 5.5 |
2021-06-11 | CVE-2021-22749 | Unspecified vulnerability in Schneider-Electric Modicon X80 Bmxnor0200H RTU Firmware Sv1.6/Sv1.7 A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists in Modicon X80 BMXNOR0200H RTU SV1.70 IR22 and prior that could cause information leak concerning the current RTU configuration including communication parameters dedicated to telemetry, when a specially crafted HTTP request is sent to the web server of the module. | 5.3 |
2021-06-11 | CVE-2021-22750 | Unspecified vulnerability in Schneider-Electric Interactive Graphical Scada System A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21041 and prior that could result in loss of data or remote code execution due to missing length checks, when a malicious CGF file is imported to IGSS Definition. | 7.8 |
2021-06-11 | CVE-2021-22751 | Unspecified vulnerability in Schneider-Electric Interactive Graphical Scada System A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of information or execution of arbitrary code due to lack of input validation, when a malicious CGF (Configuration Group File) file is imported to IGSS Definition. | 7.8 |