Vulnerabilities > Schneider Electric

DATE CVE VULNERABILITY TITLE RISK
2021-07-14 CVE-2021-22779 Authentication Bypass by Spoofing vulnerability in Schneider-Electric products
Authentication Bypass by Spoofing vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (all versions), Modicon M580 CPU (all versions - part numbers BMEP* and BMEH*), Modicon M340 CPU (all versions - part numbers BMXP34*), that could cause unauthorized access in read and write mode to the controller by spoofing the Modbus communication between the engineering software and the controller.
network
low complexity
schneider-electric CWE-290
critical
9.1
2021-07-14 CVE-2021-22780 Insufficiently Protected Credentials vulnerability in Schneider-Electric products
Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause unauthorized access to a project file protected by a password when this file is shared with untrusted sources.
local
low complexity
schneider-electric CWE-522
7.1
2021-07-14 CVE-2021-22781 Insufficiently Protected Credentials vulnerability in Schneider-Electric products
Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause a leak of SMTP credential used for mailbox authentication when an attacker can access a project file.
local
low complexity
schneider-electric CWE-522
5.5
2021-07-14 CVE-2021-22782 Missing Encryption of Sensitive Data vulnerability in Schneider-Electric products
Missing Encryption of Sensitive Data vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause an information leak allowing disclosure of network and process information, credentials or intellectual property when an attacker can access a project file.
local
low complexity
schneider-electric CWE-311
5.5
2021-06-11 CVE-2021-22749 Information Exposure vulnerability in Schneider-Electric Modicon X80 Bmxnor0200H RTU Firmware Sv1.6/Sv1.7
A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists in Modicon X80 BMXNOR0200H RTU SV1.70 IR22 and prior that could cause information leak concerning the current RTU configuration including communication parameters dedicated to telemetry, when a specially crafted HTTP request is sent to the web server of the module.
network
low complexity
schneider-electric CWE-200
5.3
2021-06-11 CVE-2021-22750 Out-of-bounds Write vulnerability in Schneider-Electric Interactive Graphical Scada System
A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21041 and prior that could result in loss of data or remote code execution due to missing length checks, when a malicious CGF file is imported to IGSS Definition.
local
low complexity
schneider-electric CWE-787
7.8
2021-06-11 CVE-2021-22751 Out-of-bounds Write vulnerability in Schneider-Electric Interactive Graphical Scada System
A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of information or execution of arbitrary code due to lack of input validation, when a malicious CGF (Configuration Group File) file is imported to IGSS Definition.
local
low complexity
schneider-electric CWE-787
7.8
2021-06-11 CVE-2021-22752 Out-of-bounds Write vulnerability in Schneider-Electric Interactive Graphical Scada System
A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution due to missing size checks, when a malicious WSP (Workspace) file is being parsed by IGSS Definition.
local
low complexity
schneider-electric CWE-787
7.8
2021-06-11 CVE-2021-22753 Out-of-bounds Read vulnerability in Schneider-Electric Interactive Graphical Scada System
A CWE-125: Out-of-bounds read vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution due to missing length checks, when a malicious WSP file is being parsed by IGSS Definition.
local
low complexity
schneider-electric CWE-125
7.8
2021-06-11 CVE-2021-22754 Out-of-bounds Write vulnerability in Schneider-Electric Interactive Graphical Scada System
A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution due to lack of proper validation of user-supplied data, when a malicious CGF file is imported to IGSS Definition.
local
low complexity
schneider-electric CWE-787
7.8