Vulnerabilities > Schneider Electric > OPC Factory Server > 3.5

DATE CVE VULNERABILITY TITLE RISK
2023-05-16 CVE-2023-2161 XXE vulnerability in Schneider-Electric OPC Factory Server
A CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that could cause unauthorized read access to the file system when a malicious configuration file is loaded on to the software by a local user. 
local
low complexity
schneider-electric CWE-611
5.5
2019-03-25 CVE-2015-1014 Uncontrolled Search Path Element vulnerability in Schneider-Electric OPC Factory Server 3.5
A successful exploit of these vulnerabilities requires the local user to load a crafted DLL file in the system directory on servers running Schneider Electric OFS v3.5 with version v7.40 of SCADA Expert Vijeo Citect/CitectSCADA, OFS v3.5 with version v7.30 of Vijeo Citect/CitectSCADA, and OFS v3.5 with version v7.20 of Vijeo Citect/CitectSCADA..
4.4
2014-04-01 CVE-2013-0662 Out-of-bounds Write vulnerability in Schneider-Electric products
Multiple stack-based buffer overflows in ModbusDrv.exe in Schneider Electric Modbus Serial Driver 1.10 through 3.2 allow remote attackers to execute arbitrary code via a large buffer-size value in a Modbus Application Header.
network
schneider-electric CWE-787
critical
9.3