Vulnerabilities > Schneider Electric > Modicon M340 Bmxp3420102 Firmware > High
DATE | CVE | VULNERABILITY TITLE | RISK |
---|---|---|---|
2023-02-01 | CVE-2021-22786 | Information Exposure vulnerability in Schneider-Electric products A CWE-200: Information Exposure vulnerability exists that could cause the exposure of sensitive information stored on the memory of the controller when communicating over the Modbus TCP protocol. | 7.5 |
2022-11-22 | CVE-2022-0222 | Improper Privilege Management vulnerability in Schneider-Electric products A CWE-269: Improper Privilege Management vulnerability exists that could cause a denial of service of the Ethernet communication of the controller when sending a specific request over SNMP. | 7.5 |
2020-12-11 | CVE-2020-7543 | Improper Check for Unusual or Exceptional Conditions vulnerability in Schneider-Electric products A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum & Modicon Premium (see security notifications for affected versions), that could cause denial of service when a specially crafted Read Physical Memory request over Modbus is sent to the controller. | 7.5 |
2020-12-11 | CVE-2020-7542 | Improper Check for Unusual or Exceptional Conditions vulnerability in Schneider-Electric products A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum & Modicon Premium (see security notifications for affected versions), that could cause denial of service when a specially crafted Read Physical Memory request over Modbus is sent to the controller. | 7.5 |
2020-12-11 | CVE-2020-7539 | Improper Check for Unusual or Exceptional Conditions vulnerability in Schneider-Electric products A CWE-754 Improper Check for Unusual or Exceptional Conditions vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause a denial of service vulnerability when a specially crafted packet is sent to the controller over HTTP. | 7.5 |
2020-12-11 | CVE-2020-7537 | Improper Check for Unusual or Exceptional Conditions vulnerability in Schneider-Electric products A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum & Modicon Premium (see security notifications for affected versions), that could cause denial of service when a specially crafted Read Physical Memory request over Modbus is sent to the controller. | 7.5 |
2020-12-11 | CVE-2020-7536 | Improper Check for Unusual or Exceptional Conditions vulnerability in Schneider-Electric products A CWE-754:Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M340 CPUs (BMXP34* versions prior to V3.30) Modicon M340 Communication Ethernet modules (BMXNOE0100 (H) versions prior to V3.4 BMXNOE0110 (H) versions prior to V6.6 BMXNOR0200H all versions), that could cause the device to be unreachable when modifying network parameters over SNMP. | 7.5 |
2020-12-11 | CVE-2020-7535 | Path Traversal vulnerability in Schneider-Electric products A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal' Vulnerability Type) vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause disclosure of information when sending a specially crafted request to the controller over HTTP. | 7.5 |
2020-01-06 | CVE-2019-6855 | Incorrect Authorization vulnerability in Schneider-Electric products Incorrect Authorization vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20) , and Modicon M580 (all versions prior to V3.10), which could cause a bypass of the authentication process between EcoStruxure Control Expert and the M340 and M580 controllers. | 7.5 |
2018-04-18 | CVE-2018-7762 | Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability in Schneider-Electric products A vulnerability exists in the web services to process SOAP requests in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200 which could allow result in a buffer overflow. | 7.5 |