Vulnerabilities > Schneider Electric > Modicon M251 Firmware > Medium

DATE CVE VULNERABILITY TITLE RISK
2024-07-11 CVE-2024-6528 Cross-site Scripting vulnerability in Schneider-Electric products
CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause a vulnerability leading to a cross-site scripting condition where attackers can have a victim’s browser run arbitrary JavaScript when they visit a page containing the injected payload.
network
low complexity
schneider-electric CWE-79
6.1
2020-04-22 CVE-2020-7488 Cleartext Transmission of Sensitive Information vulnerability in Schneider-Electric products
A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists which could leak sensitive information transmitted between the software and the Modicon M218, M241, M251, and M258 controllers.
network
low complexity
schneider-electric CWE-319
5.0
2019-05-22 CVE-2019-6820 Missing Authentication for Critical Function vulnerability in Schneider-Electric products
A CWE-306: Missing Authentication for Critical Function vulnerability exists which could cause a modification of device IP configuration (IP address, network mask and gateway IP address) when a specific Ethernet frame is received in all versions of: Modicon M100, Modicon M200, Modicon M221, ATV IMC drive controller, Modicon M241, Modicon M251, Modicon M258, Modicon LMC058, Modicon LMC078, PacDrive Eco ,PacDrive Pro, PacDrive Pro2
network
low complexity
schneider-electric CWE-306
6.4
2017-06-30 CVE-2017-6030 Insufficient Entropy vulnerability in Schneider-Electric products
A Predictable Value Range from Previous Values issue was discovered in Schneider Electric Modicon PLCs Modicon M221, firmware versions prior to Version 1.5.0.0, Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11.
network
low complexity
schneider-electric CWE-331
6.4
2017-06-30 CVE-2017-6028 Insufficiently Protected Credentials vulnerability in Schneider-Electric Modicon M241 Firmware and Modicon M251 Firmware
An Insufficiently Protected Credentials issue was discovered in Schneider Electric Modicon PLCs Modicon M241, all firmware versions, and Modicon M251, all firmware versions.
network
low complexity
schneider-electric CWE-522
5.0
2017-06-30 CVE-2017-6026 Use of Insufficiently Random Values vulnerability in Schneider-Electric Modicon M241 Firmware and Modicon M251 Firmware
A Use of Insufficiently Random Values issue was discovered in Schneider Electric Modicon PLCs Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11.
network
low complexity
schneider-electric CWE-330
6.4