2019-10-29 CVE-2019-6847 Improper Handling of Exceptional Conditions vulnerability in Schneider-Electric products
A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause a Denial of Service attack on the FTP service when upgrading the firmware with a version incompatible with the application in the controller using FTP protocol.
network
low complexity
schneider-electric CWE-755
4.0
2019-10-29 CVE-2019-6846 Cleartext Transmission of Sensitive Information vulnerability in Schneider-Electric products
A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists in Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause information disclosure when using the FTP protocol.
4.3
2019-10-29 CVE-2019-6844 Improper Handling of Exceptional Conditions vulnerability in Schneider-Electric products
A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause a Denial of Service atack on the PLC when upgrading the controller with a firmware package containing an invalid web server image using FTP protocol.
network
low complexity
schneider-electric CWE-755
4.0
2019-10-29 CVE-2019-6843 Improper Handling of Exceptional Conditions vulnerability in Schneider-Electric products
A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580 with firmware (version prior to V3.10), Modicon M340 (all firmware versions), and Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause a Denial of Service attack on the PLC when upgrading the controller with an empty firmware package using FTP protocol.
network
low complexity
schneider-electric CWE-755
4.0
2019-10-29 CVE-2019-6842 Improper Handling of Exceptional Conditions vulnerability in Schneider-Electric products
A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause a Denial of Service attack on the PLC when upgrading the firmware with a missing web server image inside the package using FTP protocol.
network
low complexity
schneider-electric CWE-755
4.0
2019-10-29 CVE-2019-6841 Improper Handling of Exceptional Conditions vulnerability in Schneider-Electric products
A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580 with firmware (version prior to V3.10), Modicon M340 (all firmware versions), and Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause a Denial of Service attack on the PLC when upgrading the firmware with no firmware image inside the package using FTP protocol.
network
low complexity
schneider-electric CWE-755
4.0