Vulnerabilities > Schneider Electric > Interactive Graphical Scada System Data Server

DATE CVE VULNERABILITY TITLE RISK
2022-02-09 CVE-2022-24310 Integer Overflow or Wraparound vulnerability in Schneider-Electric Interactive Graphical Scada System Data Server
A CWE-190: Integer Overflow or Wraparound vulnerability exists that could cause heap-based buffer overflow, leading to denial of service and potentially remote code execution when an attacker sends multiple specially crafted messages.
network
low complexity
schneider-electric CWE-190
7.5
2022-02-09 CVE-2022-24311 Path Traversal vulnerability in Schneider-Electric Interactive Graphical Scada System Data Server
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modification of an existing file by inserting at beginning of file or create a new file in the context of the Data Server potentially leading to remote code execution when an attacker sends a specially crafted message.
network
low complexity
schneider-electric CWE-22
7.5
2022-02-09 CVE-2022-24312 Path Traversal vulnerability in Schneider-Electric Interactive Graphical Scada System Data Server
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modification of an existing file by adding at end of file or create a new file in the context of the Data Server potentially leading to remote code execution when an attacker sends a specially crafted message.
network
low complexity
schneider-electric CWE-22
7.5
2022-02-09 CVE-2022-24313 Classic Buffer Overflow vulnerability in Schneider-Electric Interactive Graphical Scada System Data Server
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow potentially leading to remote code execution when an attacker sends a specially crafted message.
network
low complexity
schneider-electric CWE-120
7.5
2022-02-09 CVE-2022-24314 Out-of-bounds Read vulnerability in Schneider-Electric Interactive Graphical Scada System Data Server
A CWE-125: Out-of-bounds Read vulnerability exists that could cause memory leaks potentially resulting in denial of service when an attacker repeatedly sends a specially crafted message.
network
low complexity
schneider-electric CWE-125
5.0
2022-02-09 CVE-2022-24315 Out-of-bounds Read vulnerability in Schneider-Electric Interactive Graphical Scada System Data Server
A CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service when an attacker repeatedly sends a specially crafted message.
network
low complexity
schneider-electric CWE-125
5.0
2022-02-09 CVE-2022-24316 Improper Initialization vulnerability in Schneider-Electric Interactive Graphical Scada System Data Server
A CWE-665: Improper Initialization vulnerability exists that could cause information exposure when an attacker sends a specially crafted message.
network
low complexity
schneider-electric CWE-665
5.0
2022-02-09 CVE-2022-24317 Missing Authorization vulnerability in Schneider-Electric Interactive Graphical Scada System Data Server
A CWE-862: Missing Authorization vulnerability exists that could cause information exposure when an attacker sends a specific message.
network
low complexity
schneider-electric CWE-862
5.0