Vulnerabilities > Schneider Electric > Interactive Graphical Scada System Data Server
DATE | CVE | VULNERABILITY TITLE | RISK |
---|---|---|---|
2022-02-09 | CVE-2022-24310 | Unspecified vulnerability in Schneider-Electric Interactive Graphical Scada System Data Server A CWE-190: Integer Overflow or Wraparound vulnerability exists that could cause heap-based buffer overflow, leading to denial of service and potentially remote code execution when an attacker sends multiple specially crafted messages. | 9.8 |
2022-02-09 | CVE-2022-24311 | Unspecified vulnerability in Schneider-Electric Interactive Graphical Scada System Data Server A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modification of an existing file by inserting at beginning of file or create a new file in the context of the Data Server potentially leading to remote code execution when an attacker sends a specially crafted message. | 9.8 |
2022-02-09 | CVE-2022-24312 | Unspecified vulnerability in Schneider-Electric Interactive Graphical Scada System Data Server A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modification of an existing file by adding at end of file or create a new file in the context of the Data Server potentially leading to remote code execution when an attacker sends a specially crafted message. | 9.8 |
2022-02-09 | CVE-2022-24313 | Unspecified vulnerability in Schneider-Electric Interactive Graphical Scada System Data Server A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow potentially leading to remote code execution when an attacker sends a specially crafted message. | 9.8 |
2022-02-09 | CVE-2022-24314 | Unspecified vulnerability in Schneider-Electric Interactive Graphical Scada System Data Server A CWE-125: Out-of-bounds Read vulnerability exists that could cause memory leaks potentially resulting in denial of service when an attacker repeatedly sends a specially crafted message. | 7.5 |
2022-02-09 | CVE-2022-24315 | Unspecified vulnerability in Schneider-Electric Interactive Graphical Scada System Data Server A CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service when an attacker repeatedly sends a specially crafted message. | 7.5 |
2022-02-09 | CVE-2022-24316 | Unspecified vulnerability in Schneider-Electric Interactive Graphical Scada System Data Server A CWE-665: Improper Initialization vulnerability exists that could cause information exposure when an attacker sends a specially crafted message. | 7.5 |
2022-02-09 | CVE-2022-24317 | Unspecified vulnerability in Schneider-Electric Interactive Graphical Scada System Data Server A CWE-862: Missing Authorization vulnerability exists that could cause information exposure when an attacker sends a specific message. | 7.5 |