Vulnerabilities > Schneider Electric > Evlink Parking Evf2 Firmware

DATE CVE VULNERABILITY TITLE RISK
2022-01-28 CVE-2021-22818 Improper Restriction of Excessive Authentication Attempts vulnerability in Schneider-Electric products
A CWE-307 Improper Restriction of Excessive Authentication Attempts vulnerability exists that could allow an attacker to gain unauthorized access to the charging station web interface by performing brute force attacks.
network
low complexity
schneider-electric CWE-307
5.0
2022-01-28 CVE-2021-22819 Improper Restriction of Rendered UI Layers or Frames vulnerability in Schneider-Electric products
A CWE-1021 Improper Restriction of Rendered UI Layers or Frames vulnerability exists that could cause unintended modifications of the product settings or user accounts when deceiving the user to use the web interface rendered within iframes.
4.3
2022-01-28 CVE-2021-22820 Insufficient Session Expiration vulnerability in Schneider-Electric products
A CWE-614 Insufficient Session Expiration vulnerability exists that could allow an attacker to maintain an unauthorized access over a hijacked session to the charger station web server even after the legitimate user account holder has changed his password.
network
low complexity
schneider-electric CWE-613
7.5
2022-01-28 CVE-2021-22821 Server-Side Request Forgery (SSRF) vulnerability in Schneider-Electric products
A CWE-918 Server-Side Request Forgery (SSRF) vulnerability exists that could cause the station web server to forward requests to unintended network targets when crafted malicious parameters are submitted to the charging station web server.
network
low complexity
schneider-electric CWE-918
5.0
2022-01-28 CVE-2021-22822 Cross-site Scripting vulnerability in Schneider-Electric products
A CWE-79 Improper Neutralization of Input During Web Page Generation (?Cross-site Scripting?) vulnerability exists that could allow an attacker to impersonate the user who manages the charging station or carry out actions on their behalf when crafted malicious parameters are submitted to the charging station web server.
network
low complexity
schneider-electric CWE-79
6.1
2021-07-21 CVE-2021-22706 Cross-site Scripting vulnerability in Schneider-Electric products
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to impersonate the user who manages the charging station or carry out actions on their behalf when crafted malicious parameters are submitted to the charging station web server.
4.3
2021-07-21 CVE-2021-22707 Use of Hard-coded Credentials vulnerability in Schneider-Electric products
A CWE-798: Use of Hard-coded Credentials vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to issue unauthorized commands to the charging station web server with administrative privileges.
network
low complexity
schneider-electric CWE-798
critical
10.0
2021-07-21 CVE-2021-22708 Improper Verification of Cryptographic Signature vulnerability in Schneider-Electric products
A CWE-347: Improper Verification of Cryptographic Signature vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to craft a malicious firmware package and bypass the signature verification mechanism.
network
low complexity
schneider-electric CWE-347
6.5
2021-07-21 CVE-2021-22721 Information Exposure vulnerability in Schneider-Electric products
A CWE-200: Information Exposure vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to get limited knowledge of javascript code when crafted malicious parameters are submitted to the charging station web server.
network
low complexity
schneider-electric CWE-200
5.0
2021-07-21 CVE-2021-22722 Cross-site Scripting vulnerability in Schneider-Electric products
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Stored Cross-site Scripting') vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could cause code injection when importing a CSV file or changing station parameters.
3.5