Vulnerabilities > Schneider Electric > Ecostruxure Power Monitoring Expert > Medium
DATE | CVE | VULNERABILITY TITLE | RISK |
---|---|---|---|
2023-11-15 | CVE-2023-5986 | Open Redirect vulnerability in Schneider-Electric Ecostruxure Power Monitoring Expert 2020/2021 A CWE-601 URL Redirection to Untrusted Site vulnerability exists that could cause an openredirect vulnerability leading to a cross site scripting attack. | 6.1 |
2023-11-15 | CVE-2023-5987 | Unspecified vulnerability in Schneider-Electric Ecostruxure Power Monitoring Expert 2020/2021 A CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting) vulnerability that could cause a vulnerability leading to a cross site scripting condition where attackers can have a victim’s browser run arbitrary JavaScript when they visit a page containing the injected payload. | 6.1 |
2022-02-04 | CVE-2022-22726 | Unspecified vulnerability in Schneider-Electric Ecostruxure Power Monitoring Expert A CWE-20: Improper Input Validation vulnerability exists that could allow arbitrary files on the server to be read by authenticated users through a limited operating system service account. | 6.5 |
2022-02-04 | CVE-2022-22804 | Unspecified vulnerability in Schneider-Electric Ecostruxure Power Monitoring Expert A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could allow an authenticated attacker to view data, change settings, or impact availability of the software when the user visits a page containing the injected payload. | 5.4 |
2020-12-01 | CVE-2020-7546 | Unspecified vulnerability in Schneider-Electric products A CWE-79: Improper Neutralization of Input During Web Page Generation vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information) that could allow an attacker to perform actions on behalf of the authorized user when accessing an affected webpage. | 5.4 |
2018-12-17 | CVE-2018-7797 | Open Redirect vulnerability in Schneider-Electric products A URL redirection vulnerability exists in Power Monitoring Expert, Energy Expert (formerly Power Manager) - EcoStruxure Power Monitoring Expert (PME) v8.2 (all editions), EcoStruxure Energy Expert 1.3 (formerly Power Manager), EcoStruxure Power SCADA Operation (PSO) 8.2 Advanced Reports and Dashboards Module, EcoStruxure Power Monitoring Expert (PME) v9.0, EcoStruxure Energy Expert v2.0, and EcoStruxure Power SCADA Operation (PSO) 9.0 Advanced Reports and Dashboards Module which could cause a phishing attack when redirected to a malicious site. | 6.1 |