Vulnerabilities > Schneider Electric > Ecostruxure Operator Terminal Expert > High

DATE CVE VULNERABILITY TITLE RISK
2023-06-14 CVE-2023-1049 Code Injection vulnerability in Schneider-Electric products
A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that could cause execution of malicious code when an unsuspicious user loads a project file from the local filesystem into the HMI.
local
low complexity
schneider-electric CWE-94
7.8
2022-11-04 CVE-2022-41671 Unspecified vulnerability in Schneider-Electric products
A CWE-89: Improper Neutralization of Special Elements used in SQL Command (‘SQL Injection’) vulnerability exists that allows adversaries with local user privileges to craft a malicious SQL query and execute as part of project migration which could result in execution of malicious code.
local
low complexity
schneider-electric
7.8
2022-11-04 CVE-2022-41670 Unspecified vulnerability in Schneider-Electric products
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in the SGIUtility component that allows adversaries with local user privileges to load malicious DLL which could result in execution of malicious code.
local
low complexity
schneider-electric
7.8
2022-11-04 CVE-2022-41669 Unspecified vulnerability in Schneider-Electric products
A CWE-347: Improper Verification of Cryptographic Signature vulnerability exists in the SGIUtility component that allows adversaries with local user privileges to load a malicious DLL which could result in execution of malicious code.
local
low complexity
schneider-electric
7.8
2022-11-04 CVE-2022-41667 Unspecified vulnerability in Schneider-Electric products
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that allows adversaries with local user privileges to load a malicious DLL which could lead to execution of malicious code.
local
low complexity
schneider-electric
7.8
2022-11-04 CVE-2022-41668 Unspecified vulnerability in Schneider-Electric products
A CWE-704: Incorrect Project Conversion vulnerability exists that allows adversaries with local user privileges to load a project file from an adversary-controlled network share which could result in execution of malicious code.
local
low complexity
schneider-electric
7.8
2022-11-04 CVE-2022-41666 Unspecified vulnerability in Schneider-Electric products
A CWE-347: Improper Verification of Cryptographic Signature vulnerability exists that allows adversaries with local user privileges to load a malicious DLL which could lead to execution of malicious code.
local
low complexity
schneider-electric
7.8
2020-06-16 CVE-2020-7494 Path Traversal vulnerability in Schneider-Electric Ecostruxure Operator Terminal Expert 3.0/3.1
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD) which could cause malicious code execution when opening the project file.
local
low complexity
schneider-electric CWE-22
7.8
2020-06-16 CVE-2020-7493 SQL Injection vulnerability in Schneider-Electric Ecostruxure Operator Terminal Expert 3.0/3.1
A CWE-89: Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') vulnerability exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD) which could cause malicious code execution when opening the project file.
local
low complexity
schneider-electric CWE-89
7.8