Vulnerabilities > Schneider Electric > Ecostruxure Control Expert > Low

DATE CVE VULNERABILITY TITLE RISK
2021-07-14 CVE-2021-22782 Missing Encryption of Sensitive Data vulnerability in Schneider-Electric products
Missing Encryption of Sensitive Data vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause an information leak allowing disclosure of network and process information, credentials or intellectual property when an attacker can access a project file.
local
low complexity
schneider-electric CWE-311
2.1
2021-07-14 CVE-2021-22781 Insufficiently Protected Credentials vulnerability in Schneider-Electric products
Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause a leak of SMTP credential used for mailbox authentication when an attacker can access a project file.
local
low complexity
schneider-electric CWE-522
2.1
2021-07-14 CVE-2021-22780 Insufficiently Protected Credentials vulnerability in Schneider-Electric products
Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause unauthorized access to a project file protected by a password when this file is shared with untrusted sources.
local
low complexity
schneider-electric CWE-522
3.6
2021-07-14 CVE-2021-22778 Insufficiently Protected Credentials vulnerability in Schneider-Electric products
Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause protected derived function blocks to be read or modified by unauthorized users when accessing a project file.
local
low complexity
schneider-electric CWE-522
3.6