Vulnerabilities > Schneider Electric > Citectscada > 7.10
DATE | CVE | VULNERABILITY TITLE | RISK |
---|---|---|---|
2013-08-09 | CVE-2013-2796 | Permissions, Privileges, and Access Controls vulnerability in Schneider-Electric Citectscada, Powerlogic Scada and Vijeo Citect Schneider Electric Vijeo Citect 7.20 and earlier, CitectSCADA 7.20 and earlier, and PowerLogic SCADA 7.20 and earlier allow remote attackers to read arbitrary files, send HTTP requests to intranet servers, or cause a denial of service (CPU and memory consumption) via an XML document containing an external entity declaration in conjunction with an entity reference, related to an XML External Entity (XXE) issue. | 6.9 |
2013-04-19 | CVE-2013-3075 | Improper Restriction of Operations Within the Bounds of A Memory Buffer vulnerability in multiple products Multiple buffer overflows in ActUWzd.dll 1.0.0.1 in Mitsubishi MX Component 3, as distributed in Citect CitectFacilities 7.10 and CitectScada 7.10r1, allow remote attackers to execute arbitrary code via a long string, as demonstrated by a long WzTitle property value to a certain ActiveX control. | 10.0 |