Vulnerabilities > Schneider Electric > Bmxnor0200H Firmware > High
DATE | CVE | VULNERABILITY TITLE | RISK |
---|---|---|---|
2022-02-04 | CVE-2020-7534 | Cross-Site Request Forgery (CSRF) vulnerability in Schneider-Electric products A CWE-352: Cross-Site Request Forgery (CSRF) vulnerability exists on the web server used, that could cause a leak of sensitive data or unauthorized actions on the web server during the time the user is logged in. | 8.8 |
2020-12-11 | CVE-2020-7536 | Unspecified vulnerability in Schneider-Electric products A CWE-754:Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M340 CPUs (BMXP34* versions prior to V3.30) Modicon M340 Communication Ethernet modules (BMXNOE0100 (H) versions prior to V3.4 BMXNOE0110 (H) versions prior to V6.6 BMXNOR0200H all versions), that could cause the device to be unreachable when modifying network parameters over SNMP. | 7.5 |
2019-09-17 | CVE-2019-6831 | Improper Check for Unusual or Exceptional Conditions vulnerability in Schneider-Electric Bmxnor0200H Firmware A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module (all firmware versions), which could cause disconnection of active connections when an unusually high number of IEC 60870- 5-104 packets are received by the module on port 2404/TCP. | 8.6 |
2019-09-17 | CVE-2019-6813 | Improper Check for Unusual or Exceptional Conditions vulnerability in Schneider-Electric Bmxnor0200H Firmware and Modicon M340 Firmware A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module (all firmware versions) and Modicon M340 controller (all firmware versions), which could cause denial of service when truncated SNMP packets on port 161/UDP are received by the device. | 7.5 |
2019-09-17 | CVE-2019-6810 | Unspecified vulnerability in Schneider-Electric Bmxnor0200H Firmware CWE-284: Improper Access Control vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module (all firmware versions), which could cause the execution of commands by unauthorized users when using IEC 60870-5-104 protocol. | 8.8 |
2018-04-18 | CVE-2018-7762 | Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability in Schneider-Electric products A vulnerability exists in the web services to process SOAP requests in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200 which could allow result in a buffer overflow. | 7.5 |
2018-04-18 | CVE-2018-7759 | Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability in Schneider-Electric products A buffer overflow vulnerability exists in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200. | 7.5 |
2017-06-30 | CVE-2017-6017 | Resource Exhaustion vulnerability in Schneider-Electric products A Resource Exhaustion issue was discovered in Schneider Electric Modicon M340 PLC BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP341000, BMXP342000, BMXP3420102, BMXP3420102CL, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, and BMXP342030H. | 7.5 |