Vulnerabilities > Rockwellautomation > Micrologix 1400 A Firmware

DATE CVE VULNERABILITY TITLE RISK
2022-12-16 CVE-2022-46670 Cross-site Scripting vulnerability in Rockwellautomation products
Rockwell Automation was made aware of a vulnerability by a security researcher from Georgia Institute of Technology that the MicroLogix 1100 and 1400 controllers contain a vulnerability that may give an attacker the ability to accomplish remote code execution.
network
low complexity
rockwellautomation CWE-79
6.1
2020-03-16 CVE-2020-6990 Use of Hard-coded Credentials vulnerability in Rockwellautomation products
Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, The cryptographic key utilized to help protect the account password is hard coded into the RSLogix 500 binary file.
network
low complexity
rockwellautomation CWE-798
critical
10.0
2020-03-16 CVE-2020-6988 Improper Authentication vulnerability in Rockwellautomation products
Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, A remote, unauthenticated attacker can send a request from the RSLogix 500 software to the victim’s MicroLogix controller.
network
low complexity
rockwellautomation CWE-287
5.0
2020-03-16 CVE-2020-6984 Use of a Broken or Risky Cryptographic Algorithm vulnerability in Rockwellautomation products
Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, The cryptographic function utilized to protect the password in MicroLogix is discoverable.
network
low complexity
rockwellautomation CWE-327
5.0
2020-03-16 CVE-2020-6980 Cleartext Storage of Sensitive Information vulnerability in Rockwellautomation products
Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, If Simple Mail Transfer Protocol (SMTP) account data is saved in RSLogix 500, a local attacker with access to a victim’s project may be able to gather SMTP server authentication data as it is written to the project file in cleartext.
local
low complexity
rockwellautomation CWE-312
2.1
2019-04-25 CVE-2019-10955 Open Redirect vulnerability in Rockwellautomation products
In Rockwell Automation MicroLogix 1400 Controllers Series A, All Versions Series B, v15.002 and earlier, MicroLogix 1100 Controllers v14.00 and earlier, CompactLogix 5370 L1 controllers v30.014 and earlier, CompactLogix 5370 L2 controllers v30.014 and earlier, CompactLogix 5370 L3 controllers (includes CompactLogix GuardLogix controllers) v30.014 and earlier, an open redirect vulnerability could allow a remote unauthenticated attacker to input a malicious link to redirect users to a malicious site that could run or download arbitrary malware on the user’s machine.
5.8