Vulnerabilities > Philips
DATE | CVE | VULNERABILITY TITLE | RISK |
---|---|---|---|
2018-03-26 | CVE-2018-5466 | Improper Certificate Validation vulnerability in Philips Intellispace Portal 8.0/9.0 Philips IntelliSpace Portal all versions of 8.0.x, and 7.0.x have a self-signed SSL certificate vulnerability this could allow an attacker to gain unauthorized access to resources and information. | 7.5 |
2018-03-26 | CVE-2018-5464 | Improper Certificate Validation vulnerability in Philips Intellispace Portal 8.0/9.0 Philips IntelliSpace Portal all versions of 8.0.x, and 7.0.x have an untrusted SSL certificate vulnerability this could allow an attacker to gain unauthorized access to resources and information. | 7.5 |
2018-03-26 | CVE-2018-5462 | Improper Certificate Validation vulnerability in Philips Intellispace Portal 8.0/9.0 Philips IntelliSpace Portal all versions of 8.0.x, and 7.0.x have an SSL incorrect hostname certificate vulnerability this could allow an attacker to gain unauthorized access to resources and information. | 7.5 |
2018-03-26 | CVE-2018-5458 | Use of a Broken or Risky Cryptographic Algorithm vulnerability in Philips Intellispace Portal 8.0/9.0 Philips IntelliSpace Portal all versions of 8.0.x, and 7.0.x have a vulnerability using SSL legacy encryption that could allow an attacker to gain unauthorized access to resources and information. | 7.5 |
2018-03-26 | CVE-2018-5454 | Unspecified vulnerability in Philips Intellispace Portal 8.0/9.0 Philips IntelliSpace Portal all versions of 8.0.x, and 7.0.x have a vulnerability where code debugging methods are enabled, which could allow an attacker to remotely execute arbitrary code during runtime. | 8.1 |
2018-03-20 | CVE-2018-5438 | Insufficient Session Expiration vulnerability in Philips Intellispace Cardiovascular 2.3.0 Philips ISCV application prior to version 2.3.0 has an insufficient session expiration vulnerability where an attacker could reuse the session of a previously logged in user. | 6.3 |
2017-11-17 | CVE-2017-14111 | Insufficiently Protected Credentials vulnerability in Philips Intellispace Cardiovascular and Xcelera The workstation logging function in Philips IntelliSpace Cardiovascular (ISCV) 2.3.0 and earlier and Xcelera R4.1L1 and earlier records domain authentication credentials, which if accessed allows an attacker to use credentials to access the application, or other user entitlements. | 7.2 |
2017-10-01 | CVE-2017-14797 | Inadequate Encryption Strength vulnerability in Philips HUE Bridge Bsb002 Firmware 1707040932 Lack of Transport Encryption in the public API in Philips Hue Bridge BSB002 SW 1707040932 allows remote attackers to read API keys (and consequently bypass the pushlink protection mechanism, and obtain complete control of the connected accessories) by leveraging the ability to sniff HTTP traffic on the local intranet network. | 7.5 |
2017-04-12 | CVE-2017-0199 | Microsoft Office 2007 SP3, Microsoft Office 2010 SP2, Microsoft Office 2013 SP1, Microsoft Office 2016, Microsoft Windows Vista SP2, Windows Server 2008 SP2, Windows 7 SP1, Windows 8.1 allow remote attackers to execute arbitrary code via a crafted document, aka "Microsoft Office/WordPad Remote Code Execution Vulnerability w/Windows API." | 7.8 |
2017-04-10 | CVE-2015-2884 | Information Exposure vulnerability in Philips In.Sight B12037 Philips In.Sight B120/37 allows remote attackers to obtain sensitive information via a direct request, related to yoics.net URLs, stream.m3u8 URIs, and cam_service_enable.cgi. | 7.5 |