Vulnerabilities > Omron > Nj501 4500 Firmware
DATE | CVE | VULNERABILITY TITLE | RISK |
---|---|---|---|
2024-06-24 | CVE-2024-33687 | Insufficient Verification of Data Authenticity vulnerability in Omron products Insufficient verification of data authenticity issue exists in NJ Series CPU Unit all versions and NX Series CPU Unit all versions. | 7.5 |
2023-06-19 | CVE-2023-27396 | Missing Authentication for Critical Function vulnerability in Omron products FINS (Factory Interface Network Service) is a message communication protocol, which is designed to be used in closed FA (Factory Automation) networks, and is used in FA networks composed of OMRON products. | 9.8 |
2022-07-26 | CVE-2022-31206 | Improper Verification of Cryptographic Signature vulnerability in Omron products The Omron SYSMAC Nx product family PLCs (NJ series, NY series, NX series, and PMAC series) through 2022-005-18 lack cryptographic authentication. | 9.8 |
2022-07-04 | CVE-2022-33208 | Authentication Bypass by Capture-replay vulnerability in Omron products Authentication bypass by capture-replay vulnerability exists in Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software 'Sysmac Studio' all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier, which may allow a remote attacker who can analyze the communication between the affected controller and automation software 'Sysmac Studio' and/or a Programmable Terminal (PT) to access the controller. | 8.1 |
2022-07-04 | CVE-2022-33971 | Authentication Bypass by Capture-replay vulnerability in Omron products Authentication bypass by capture-replay vulnerability exists in Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, and Machine automation controller NJ series all models V 1.48 and earlier, which may allow an adjacent attacker who can analyze the communication between the controller and the specific software used by OMRON internally to cause a denial-of-service (DoS) condition or execute a malicious program. | 7.5 |
2022-07-04 | CVE-2022-34151 | Use of Hard-coded Credentials vulnerability in Omron products Use of hard-coded credentials vulnerability exists in Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software 'Sysmac Studio' all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier, which may allow a remote attacker who successfully obtained the user credentials by analyzing the affected product to access the controller. | 8.1 |