DATE | CVE | VULNERABILITY TITLE | RISK |
---|---|---|---|
2022-05-13 | CVE-2021-33013 | Missing Authorization vulnerability in Myscada Mypro 7/7.0.26/8.20.0 mySCADA myPRO versions prior to 8.20.0 does not restrict unauthorized read access to sensitive system information. | 7.5 |
2022-04-11 | CVE-2022-0999 | OS Command Injection vulnerability in Myscada Mypro An authenticated user may be able to misuse parameters to inject arbitrary operating system commands into mySCADA myPRO versions 8.25.0 and prior. | 8.8 |
2021-12-23 | CVE-2021-22657 | Unspecified vulnerability in Myscada Mypro 7/7.0.26/8.20.0 mySCADA myPRO: Versions 8.20.0 and prior has a feature where the API password can be specified, which may allow an attacker to inject arbitrary operating system commands through a specific parameter. | 9.8 |
2021-12-23 | CVE-2021-23198 | Unspecified vulnerability in Myscada Mypro 7/7.0.26/8.20.0 mySCADA myPRO: Versions 8.20.0 and prior has a feature where the password can be specified, which may allow an attacker to inject arbitrary operating system commands through a specific parameter. | 9.8 |
2021-12-23 | CVE-2021-43981 | Unspecified vulnerability in Myscada Mypro 7/7.0.26/8.20.0 mySCADA myPRO: Versions 8.20.0 and prior has a feature to send emails, which may allow an attacker to inject arbitrary operating system commands through a specific parameter. | 9.8 |
2021-12-23 | CVE-2021-43984 | Unspecified vulnerability in Myscada Mypro 7/7.0.26/8.20.0 mySCADA myPRO: Versions 8.20.0 and prior has a feature where the firmware can be updated, which may allow an attacker to inject arbitrary operating system commands through a specific parameter. | 9.8 |
2021-12-23 | CVE-2021-43985 | Unspecified vulnerability in Myscada Mypro 7/7.0.26/8.20.0 An unauthenticated remote attacker can access mySCADA myPRO Versions 8.20.0 and prior without any form of authentication or authorization. | 9.8 |
2021-12-23 | CVE-2021-43987 | Unspecified vulnerability in Myscada Mypro 7/7.0.26/8.20.0 An additional, nondocumented administrative account exists in mySCADA myPRO Versions 8.20.0 and prior that is not exposed through the web interface, which cannot be deleted or changed through the regular web interface. | 9.8 |
2021-12-23 | CVE-2021-43989 | Use of a Broken or Risky Cryptographic Algorithm vulnerability in Myscada Mypro 7/7.0.26/8.20.0 mySCADA myPRO Versions 8.20.0 and prior stores passwords using MD5, which may allow an attacker to crack the previously retrieved password hashes. | 7.5 |
2021-12-23 | CVE-2021-44453 | Unspecified vulnerability in Myscada Mypro 7/7.0.26/8.20.0 mySCADA myPRO: Versions 8.20.0 and prior has a vulnerable debug interface which includes a ping utility, which may allow an attacker to inject arbitrary operating system commands. | 9.8 |