Vulnerabilities > Mitsubishielectric > High
DATE | CVE | VULNERABILITY TITLE | RISK |
---|---|---|---|
2021-06-11 | CVE-2021-20591 | Resource Exhaustion vulnerability in Mitsubishielectric products Uncontrolled Resource Consumption vulnerability in Mitsubishi Electric MELSEC iQ-R series CPU modules (R00/01/02CPU all versions, R04/08/16/32/120(EN)CPU all versions, R08/16/32/120SFCPU all versions, R08/16/32/120PCPU all versions, R08/16/32/120PSFCPU all versions) allows a remote unauthenticated attacker to prevent legitimate clients from connecting to the MELSOFT transmission port (TCP/IP) by not closing a connection properly, which may lead to a denial of service (DoS) condition. | 7.8 |
2021-04-22 | CVE-2021-20590 | Improper Authentication vulnerability in Mitsubishielectric products Improper authentication vulnerability in GOT2000 series GT27 model VNC server versions 01.39.010 and prior, GOT2000 series GT25 model VNC server versions 01.39.010 and prior, GOT2000 series GT21 model GT2107-WTBD VNC server versions 01.40.000 and prior, GOT2000 series GT21 model GT2107-WTSD VNC server versions 01.40.000 and prior, GOT SIMPLE series GS21 model GS2110-WTBD-N VNC server versions 01.40.000 and prior and GOT SIMPLE series GS21 model GS2107-WTBD-N VNC server versions 01.40.000 and prior allows a remote unauthenticated attacker to gain unauthorized access via specially crafted packets when the "VNC server" function is used. | 7.5 |
2021-01-29 | CVE-2021-20586 | Unspecified vulnerability in Mitsubishielectric products Resource management errors vulnerability in a robot controller of MELFA FR Series(controller "CR800-*V*D" of RV-*FR***-D-* all versions, controller "CR800-*HD" of RH-*FRH***-D-* all versions, controller "CR800-*HRD" of RH-*FRHR***-D-* all versions, controller "CR800-*V*R with R16RTCPU" of RV-*FR***-R-* all versions, controller "CR800-*HR with R16RTCPU" of RH-*FRH***-R-* all versions, controller "CR800-*HRR with R16RTCPU" of RH-*FRHR***-R-* all versions, controller "CR800-*V*Q with Q172DSRCPU" of RV-*FR***-Q-* all versions, controller "CR800-*HQ with Q172DSRCPU" of RH-*FRH***-Q-* all versions, controller "CR800-*HRQ with Q172DSRCPU" of RH-*FRHR***-Q-* all versions) and a robot controller of MELFA CR Series(controller "CR800-CVD" of RV-8CRL-D-* all versions, controller "CR800-CHD" of RH-*CRH**-D-* all versions) as well as a cooperative robot ASSISTA(controller "CR800-05VD" of RV-5AS-D-* all versions) allows a remote unauthenticated attacker to cause a DoS of the execution of the robot program and the Ethernet communication by sending a large amount of packets in burst over a short period of time. | 7.8 |
2020-11-30 | CVE-2020-16850 | Resource Exhaustion vulnerability in Mitsubishielectric products Mitsubishi MELSEC iQ-R Series PLCs with firmware 49 allow an unauthenticated attacker to halt the industrial process by sending a crafted packet over the network. | 7.8 |
2020-11-20 | CVE-2020-5668 | Resource Exhaustion vulnerability in Mitsubishielectric products Uncontrolled resource consumption vulnerability in MELSEC iQ-R Series modules (R00/01/02CPU firmware version '19' and earlier, R04/08/16/32/120 (EN) CPU firmware version '51' and earlier, R08/16/32/120SFCPU firmware version '22' and earlier, R08/16/32/120PCPU firmware version '25' and earlier, R08/16/32/120PSFCPU firmware version '06' and earlier, RJ71EN71 firmware version '47' and earlier, RJ71GF11-T2 firmware version '47' and earlier, RJ72GF15-T2 firmware version '07' and earlier, RJ71GP21-SX firmware version '47' and earlier, RJ71GP21S-SX firmware version '47' and earlier, and RJ71GN11-T2 firmware version '11' and earlier) allows a remote unauthenticated attacker to cause an error in a CPU unit and cause a denial-of-service (DoS) condition in execution of the program and its communication, or to cause a denial-of-service (DoS) condition in communication via the unit by receiving a specially crafted SLMP packet | 7.8 |
2020-11-16 | CVE-2020-5666 | Resource Exhaustion vulnerability in Mitsubishielectric products Uncontrolled resource consumption vulnerability in MELSEC iQ-R Series CPU Modules (R00/01/02CPU Firmware versions from '05' to '19' and R04/08/16/32/120(EN)CPU Firmware versions from '35' to '51') allows a remote attacker to cause an error in a CPU unit via a specially crafted HTTP packet, which may lead to a denial-of-service (DoS) condition in execution of the program and its communication. | 7.1 |
2020-11-06 | CVE-2020-5647 | Unspecified vulnerability in Mitsubishielectric Coreos Improper access control vulnerability in TCP/IP function included in the firmware of GT14 Model of GOT 1000 series (GT1455-QTBDE CoreOS version ’05.65.00.BD’ and earlier, GT1450-QMBDE CoreOS version ’05.65.00.BD’ and earlier, GT1450-QLBDE CoreOS version ’05.65.00.BD’ and earlier, GT1455HS-QTBDE CoreOS version ’05.65.00.BD’ and earlier, and GT1450HS-QMBDE CoreOS version ’05.65.00.BD’ and earlier) allows a remote unauthenticated attacker to stop the network functions of the products or execute a malicious program via a specially crafted packet. | 7.5 |
2020-11-06 | CVE-2020-5644 | Classic Buffer Overflow vulnerability in Mitsubishielectric Coreos Buffer overflow vulnerability in TCP/IP function included in the firmware of GT14 Model of GOT 1000 series (GT1455-QTBDE CoreOS version "05.65.00.BD" and earlier, GT1450-QMBDE CoreOS version "05.65.00.BD" and earlier, GT1450-QLBDE CoreOS version "05.65.00.BD" and earlier, GT1455HS-QTBDE CoreOS version "05.65.00.BD" and earlier, and GT1450HS-QMBDE CoreOS version "05.65.00.BD" and earlier) allows a remote unauthenticated attacker to stop the network functions of the products or execute a malicious program via a specially crafted packet. | 7.5 |
2020-11-02 | CVE-2020-5656 | Unspecified vulnerability in Mitsubishielectric products Improper access control vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before) allows a remote unauthenticated attacker to stop the network functions of the products or execute a malicious program via a specially crafted packet. | 7.5 |
2020-11-02 | CVE-2020-5653 | Classic Buffer Overflow vulnerability in Mitsubishielectric products Buffer overflow vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before) allows a remote unauthenticated attacker to stop the network functions of the products or execute a malicious program via a specially crafted packet. | 7.5 |