Vulnerabilities > Meross
DATE | CVE | VULNERABILITY TITLE | RISK |
---|---|---|---|
2024-01-23 | CVE-2023-46892 | Authentication Bypass by Capture-replay vulnerability in Meross Msh30Q Firmware 4.5.23 The radio frequency communication protocol being used by Meross MSH30Q 4.5.23 is vulnerable to replay attacks, allowing attackers to record and replay previously captured communication to execute unauthorized commands or actions (e.g., thermostat's temperature). | 8.8 |
2024-01-23 | CVE-2023-46889 | Cleartext Transmission of Sensitive Information vulnerability in Meross Msh30Q Firmware 4.5.23 Meross MSH30Q 4.5.23 is vulnerable to Cleartext Transmission of Sensitive Information. | 5.7 |
2021-11-05 | CVE-2021-3774 | Cleartext Transmission of Sensitive Information vulnerability in Meross Mss550X Firmware 3.1.3 Meross Smart Wi-Fi 2 Way Wall Switch (MSS550X), on its 3.1.3 version and before, creates an open Wi-Fi Access Point without the required security measures in its initial setup. | 6.5 |
2021-10-07 | CVE-2021-35067 | Authentication Bypass by Capture-replay vulnerability in Meross Msg100 Firmware Meross MSG100 devices before 3.2.3 allow an attacker to replay the same data or similar data (e.g., an attacker who sniffs a Close message can transmit an acceptable Open message). | 8.1 |
2018-05-02 | CVE-2018-6401 | Use of Hard-coded Credentials vulnerability in Meross Mss110 Firmware 1.1.24 Meross MSS110 devices before 1.1.24 contain a TELNET listener providing access for an undocumented admin account with a blank password. | 9.8 |
2018-05-02 | CVE-2018-10544 | Improper Authentication vulnerability in Meross Mss110 Firmware 1.1.24 Meross MSS110 devices through 1.1.24 contain an unauthenticated admin.htm administrative interface. | 9.8 |