2022-07-27 | CVE-2022-36946 | nfqnl_mangle in net/netfilter/nfnetlink_queue.c in the Linux kernel through 5.18.14 allows remote attackers to cause a denial of service (panic) because, in the case of an nf_queue verdict with a one-byte nfta_payload attribute, an skb_pull can encounter a negative skb->len. | 7.5 |
2022-07-27 | CVE-2022-36879 | An issue was discovered in the Linux kernel through 5.18.14. | 5.5 |
2022-07-18 | CVE-2021-33655 | Out-of-bounds Write vulnerability in multiple products When sending malicous data to kernel by ioctl cmd FBIOPUT_VSCREENINFO,kernel will write memory out of bounds. | 6.7 |
2022-07-18 | CVE-2021-33656 | Out-of-bounds Write vulnerability in multiple products When setting font with malicous data by ioctl cmd PIO_FONT,kernel will write memory out of bounds. | 6.8 |
2022-07-06 | CVE-2022-2318 | Use After Free vulnerability in multiple products There are use-after-free vulnerabilities caused by timer handler in net/rose/rose_timer.c of linux that allow attackers to crash linux kernel without any privileges. | 5.5 |
2022-07-05 | CVE-2022-26365 | Memory Leak vulnerability in multiple products Linux disk/nic frontends data leaks T[his CNA information record relates to multiple CVEs; the text explains which aspects/vulnerabilities correspond to which CVE.] Linux Block and Network PV device frontends don't zero memory regions before sharing them with the backend (CVE-2022-26365, CVE-2022-33740). | 7.1 |
2022-07-05 | CVE-2022-33740 | Improper Cross-boundary Removal of Sensitive Data vulnerability in multiple products Linux disk/nic frontends data leaks T[his CNA information record relates to multiple CVEs; the text explains which aspects/vulnerabilities correspond to which CVE.] Linux Block and Network PV device frontends don't zero memory regions before sharing them with the backend (CVE-2022-26365, CVE-2022-33740). | 7.1 |
2022-07-05 | CVE-2022-33741 | Information Exposure vulnerability in multiple products Linux disk/nic frontends data leaks T[his CNA information record relates to multiple CVEs; the text explains which aspects/vulnerabilities correspond to which CVE.] Linux Block and Network PV device frontends don't zero memory regions before sharing them with the backend (CVE-2022-26365, CVE-2022-33740). | 7.1 |
2022-07-05 | CVE-2022-33742 | Information Exposure vulnerability in multiple products Linux disk/nic frontends data leaks T[his CNA information record relates to multiple CVEs; the text explains which aspects/vulnerabilities correspond to which CVE.] Linux Block and Network PV device frontends don't zero memory regions before sharing them with the backend (CVE-2022-26365, CVE-2022-33740). | 7.1 |
2022-07-05 | CVE-2022-33744 | Arm guests can cause Dom0 DoS via PV devices When mapping pages of guests on Arm, dom0 is using an rbtree to keep track of the foreign mappings. | 4.7 |