Vulnerabilities > Use of Hard-coded Credentials
DATE | CVE | VULNERABILITY TITLE | RISK |
---|---|---|---|
2020-06-29 | CVE-2020-15317 | Use of Hard-coded Credentials vulnerability in Zyxel Cloudcnm Secumanager 3.1.0/3.1.1 Zyxel CloudCNM SecuManager 3.1.0 and 3.1.1 has a hardcoded RSA SSH key for the root account within the /opt/axess chroot directory tree. | 5.9 |
2020-06-29 | CVE-2020-15316 | Use of Hard-coded Credentials vulnerability in Zyxel Cloudcnm Secumanager 3.1.0/3.1.1 Zyxel CloudCNM SecuManager 3.1.0 and 3.1.1 has a hardcoded ECDSA SSH key for the root account within the /opt/axess chroot directory tree. | 5.9 |
2020-06-29 | CVE-2020-15315 | Use of Hard-coded Credentials vulnerability in Zyxel Cloudcnm Secumanager 3.1.0/3.1.1 Zyxel CloudCNM SecuManager 3.1.0 and 3.1.1 has a hardcoded DSA SSH key for the root account within the /opt/axess chroot directory tree. | 5.9 |
2020-06-29 | CVE-2020-15314 | Use of Hard-coded Credentials vulnerability in Zyxel Cloudcnm Secumanager 3.1.0/3.1.1 Zyxel CloudCNM SecuManager 3.1.0 and 3.1.1 has a hardcoded RSA SSH key for the root account. | 5.9 |
2020-06-29 | CVE-2020-15313 | Use of Hard-coded Credentials vulnerability in Zyxel Cloudcnm Secumanager 3.1.0/3.1.1 Zyxel CloudCNM SecuManager 3.1.0 and 3.1.1 has a hardcoded ECDSA SSH key for the root account. | 5.9 |
2020-06-29 | CVE-2020-15312 | Use of Hard-coded Credentials vulnerability in Zyxel Cloudcnm Secumanager 3.1.0/3.1.1 Zyxel CloudCNM SecuManager 3.1.0 and 3.1.1 has a hardcoded DSA SSH key for the root account. | 5.9 |
2020-06-29 | CVE-2020-8573 | Use of Hard-coded Credentials vulnerability in Netapp HCI H610S Firmware The NetApp HCI H610C, H615C and H610S Baseboard Management Controllers (BMC) are shipped with a documented default account and password that should be changed during the initial node setup. | 6.5 |
2020-06-29 | CVE-2020-12047 | Use of Hard-coded Credentials vulnerability in Baxter Sigma Spectrum Infusion System Firmware 8.0 The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24), when used with a Baxter Spectrum v8.x (model 35700BAX2) in a factory-default wireless configuration enables an FTP service with hard-coded credentials. | 9.8 |
2020-06-29 | CVE-2020-12045 | Use of Hard-coded Credentials vulnerability in Baxter Sigma Spectrum Infusion System Firmware 8.0 The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) when used in conjunction with a Baxter Spectrum v8.x (model 35700BAX2), operates a Telnet service on Port 1023 with hard-coded credentials. | 9.8 |
2020-06-29 | CVE-2020-12039 | Use of Hard-coded Credentials vulnerability in Baxter Sigma Spectrum Infusion System Firmware 6.0/6.05/8.0 Baxter Sigma Spectrum Infusion Pumps Sigma Spectrum Infusion System v's6.x model 35700BAX & Baxter Spectrum Infusion System v's8.x model 35700BAX2 contain hardcoded passwords when physically entered on the keypad provide access to biomedical menus including device settings, view calibration values, network configuration of Sigma Spectrum WBM if installed. | 2.4 |