Vulnerabilities > Out-of-bounds Read
DATE | CVE | VULNERABILITY TITLE | RISK |
---|---|---|---|
2022-04-14 | CVE-2021-40400 | Out-of-bounds Read vulnerability in Gerbv Project Gerbv 2.7.0 An out-of-bounds read vulnerability exists in the RS-274X aperture macro outline primitive functionality of Gerbv 2.7.0 and dev (commit b5f1eacd) and the forked version of Gerbv (commit d7f42a9a). | 7.5 |
2022-04-14 | CVE-2021-40402 | Out-of-bounds Read vulnerability in Gerbv Project Gerbv 2.7.0/2.7.1/2.8.0 An out-of-bounds read vulnerability exists in the RS-274X aperture macro multiple outline primitives functionality of Gerbv 2.7.0 and dev (commit b5f1eacd), and Gerbv forked 2.7.1 and 2.8.0. | 7.5 |
2022-04-14 | CVE-2021-40424 | Out-of-bounds Read vulnerability in Webroot Secureanywhere 21.4 An out-of-bounds read vulnerability exists in the IOCTL GetProcessCommand and B_03 of Webroot Secure Anywhere 21.4. | 6.5 |
2022-04-14 | CVE-2021-40425 | Out-of-bounds Read vulnerability in Webroot Secureanywhere 21.4 An out-of-bounds read vulnerability exists in the IOCTL GetProcessCommand and B_03 of Webroot Secure Anywhere 21.4. | 6.5 |
2022-04-13 | CVE-2022-27523 | Out-of-bounds Read vulnerability in Autodesk DWG Trueview A buffer over-read can be exploited in Autodesk TrueView 2022 may lead to an exposure of sensitive information or a crash through using a maliciously crafted DWG file as an Input. | 7.1 |
2022-04-13 | CVE-2022-27524 | Out-of-bounds Read vulnerability in Autodesk DWG Trueview An out-of-bounds read can be exploited in Autodesk TrueView 2022 may lead to an exposure of sensitive information or a crash through using a maliciously crafted DWG file as an Input. | 7.1 |
2022-04-12 | CVE-2021-39805 | Out-of-bounds Read vulnerability in Google Android 12.0/12.1 In l2cble_process_sig_cmd of l2c_ble.cc, there is a possible out of bounds read due to a missing bounds check. | 6.5 |
2022-04-12 | CVE-2021-39809 | Out-of-bounds Read vulnerability in Google Android In avrc_ctrl_pars_vendor_rsp of avrc_pars_ct.cc, there is a possible out of bounds read due to a missing bounds check. | 7.5 |
2022-04-12 | CVE-2022-26380 | Out-of-bounds Read vulnerability in Siemens products A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. | 7.5 |
2022-04-12 | CVE-2022-28661 | Out-of-bounds Read vulnerability in Siemens Simcenter Femap A vulnerability has been identified in Simcenter Femap (All versions < V2022.1.2). | 8.8 |