Vulnerabilities > Improper Handling of Exceptional Conditions
DATE | CVE | VULNERABILITY TITLE | RISK |
---|---|---|---|
2019-05-22 | CVE-2019-6807 | Improper Handling of Exceptional Conditions vulnerability in Schneider-Electric products A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a possible denial of service when writing sensitive application variables to the controller over Modbus. | 7.5 |
2019-05-22 | CVE-2018-7852 | Improper Handling of Exceptional Conditions vulnerability in Schneider-Electric products A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause denial of service when an invalid private command parameter is sent to the controller over Modbus. | 7.5 |
2019-05-22 | CVE-2018-7849 | Improper Handling of Exceptional Conditions vulnerability in Schneider-Electric products A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum and Modicon Premium which could cause a possible Denial of Service due to improper data integrity check when sending files the controller over Modbus. | 7.5 |
2019-05-16 | CVE-2019-1858 | Improper Handling of Exceptional Conditions vulnerability in Cisco Nx-Os A vulnerability in the Simple Network Management Protocol (SNMP) input packet processor of Cisco FXOS Software and Cisco NX-OS Software could allow an unauthenticated, remote attacker to cause the SNMP application to leak system memory, which could cause an affected device to restart unexpectedly. | 8.6 |
2019-05-15 | CVE-2019-1731 | Improper Handling of Exceptional Conditions vulnerability in Cisco Nx-Os A vulnerability in the SSH CLI key management functionality of Cisco NX-OS Software could allow an authenticated, local attacker to expose a user's private SSH key to all authenticated users on the targeted device. | 4.4 |
2019-05-14 | CVE-2019-10917 | Improper Handling of Exceptional Conditions vulnerability in Siemens products A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions < V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions < V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions < V7.5 Upd 3). | 5.5 |
2019-05-07 | CVE-2019-10742 | Improper Handling of Exceptional Conditions vulnerability in Axios Axios up to and including 0.18.0 allows attackers to cause a denial of service (application crash) by continuing to accepting content after maxContentLength is exceeded. | 7.5 |
2019-05-06 | CVE-2019-3565 | Improper Handling of Exceptional Conditions vulnerability in Facebook Thrift Legacy C++ Facebook Thrift servers (using cpp instead of cpp2) would not error upon receiving messages with containers of fields of unknown type. | 7.5 |
2019-05-06 | CVE-2019-3564 | Improper Handling of Exceptional Conditions vulnerability in Facebook Thrift Go Facebook Thrift servers would not error upon receiving messages with containers of fields of unknown type. | 7.5 |
2019-05-06 | CVE-2019-3559 | Improper Handling of Exceptional Conditions vulnerability in Facebook Thrift Java Facebook Thrift servers would not error upon receiving messages with containers of fields of unknown type. | 7.5 |