Vulnerabilities > Cleartext Transmission of Sensitive Information

DATE CVE VULNERABILITY TITLE RISK
2023-06-01 CVE-2023-33960 Cleartext Transmission of Sensitive Information vulnerability in Openproject
OpenProject is web-based project management software.
network
low complexity
openproject CWE-319
7.5
2023-05-31 CVE-2023-33730 Cleartext Transmission of Sensitive Information vulnerability in Escanav Escan Management Console 14.0.1400.2281
Privilege Escalation in the "GetUserCurrentPwd" function in Microworld Technologies eScan Management Console 14.0.1400.2281 allows any remote attacker to retrieve password of any admin or normal user in plain text format.
network
low complexity
escanav CWE-319
critical
9.8
2023-05-31 CVE-2023-28348 Cleartext Transmission of Sensitive Information vulnerability in Faronics Insight 10.0.19045
An issue was discovered in Faronics Insight 10.0.19045 on Windows.
network
high complexity
faronics CWE-319
7.4
2023-05-26 CVE-2023-33187 Cleartext Transmission of Sensitive Information vulnerability in Highlight
Highlight is an open source, full-stack monitoring platform.
network
low complexity
highlight CWE-319
6.5
2023-05-22 CVE-2023-31193 Cleartext Transmission of Sensitive Information vulnerability in Snapone Orvc
Snap One OvrC Pro versions prior to 7.3 use HTTP connections when downloading a program from their servers.
network
low complexity
snapone CWE-319
7.5
2023-05-22 CVE-2022-46680 Cleartext Transmission of Sensitive Information vulnerability in Schneider-Electric products
A CWE-319: Cleartext transmission of sensitive information vulnerability exists that could cause disclosure of sensitive information, denial of service, or modification of data if an attacker is able to intercept network traffic.
network
low complexity
schneider-electric CWE-319
critical
9.8
2023-05-17 CVE-2023-0864 Cleartext Transmission of Sensitive Information vulnerability in ABB products
Cleartext Transmission of Sensitive Information vulnerability in ABB Terra AC wallbox (UL40/80A), ABB Terra AC wallbox (UL32A), ABB Terra AC wallbox (CE) (Terra AC MID), ABB Terra AC wallbox (CE) Terra AC Juno CE, ABB Terra AC wallbox (CE) Terra AC PTB, ABB Terra AC wallbox (CE) Symbiosis, ABB Terra AC wallbox (JP).This issue affects Terra AC wallbox (UL40/80A): from 1.0;0 through 1.5.5; Terra AC wallbox (UL32A) : from 1.0;0 through 1.6.5; Terra AC wallbox (CE) (Terra AC MID): from 1.0;0 through 1.6.5; Terra AC wallbox (CE) Terra AC Juno CE: from 1.0;0 through 1.6.5; Terra AC wallbox (CE) Terra AC PTB : from 1.0;0 through 1.5.25; Terra AC wallbox (CE) Symbiosis: from 1.0;0 through 1.2.7; Terra AC wallbox (JP): from 1.0;0 through 1.6.5.
low complexity
abb CWE-319
4.3
2023-05-15 CVE-2023-32784 Cleartext Transmission of Sensitive Information vulnerability in Keepass
In KeePass 2.x before 2.54, it is possible to recover the cleartext master password from a memory dump, even when a workspace is locked or no longer running.
network
low complexity
keepass CWE-319
7.5
2023-05-10 CVE-2023-30354 Cleartext Transmission of Sensitive Information vulnerability in Tenda CP3 Firmware 11.10.00.2211041355
Shenzen Tenda Technology IP Camera CP3 V11.10.00.2211041355 does not defend against physical access to U-Boot via the UART: the Wi-Fi password is shown, and the hardcoded boot password can be inserted for console access.
network
low complexity
tenda CWE-319
critical
9.8
2023-05-10 CVE-2023-25070 Cleartext Transmission of Sensitive Information vulnerability in Seiko-Sol products
Cleartext transmission of sensitive information exists in SkyBridge MB-A100/110 firmware Ver.
network
low complexity
seiko-sol CWE-319
6.5