2023-08-31 | CVE-2023-4162 | Resource Exhaustion vulnerability in Brocade Fabric Operating System 9.0.1E/9.1.1 A segmentation fault can occur in Brocade Fabric OS after Brocade Fabric OS v9.0 and before Brocade Fabric OS v9.2.0a through the passwdcfg command. | 4.4 |
2022-06-02 | CVE-2022-27774 | Insufficiently Protected Credentials vulnerability in multiple products An insufficiently protected credentials vulnerability exists in curl 4.9 to and include curl 7.82.0 are affected that could allow an attacker to extract credentials when follows HTTP(S) redirects is used with authentication could leak credentials to other services that exist on different protocols or port numbers. | 5.7 |
2022-06-02 | CVE-2022-27776 | Insufficiently Protected Credentials vulnerability in multiple products A insufficiently protected credentials vulnerability in fixed in curl 7.83.0 might leak authentication or cookie header data on HTTP redirects to the same host but another port number. | 6.5 |
2022-05-09 | CVE-2022-28161 | Information Exposure Through Log Files vulnerability in Brocade Sannav An information exposure through log file vulnerability in Brocade SANNav versions before Brocade SANnav 2.2.0 could allow an authenticated, local attacker to view sensitive information such as ssh passwords in filetansfer.log in debug mode. | 5.5 |
2020-05-27 | CVE-2020-13632 | NULL Pointer Dereference vulnerability in multiple products ext/fts3/fts3_snippet.c in SQLite before 3.32.0 has a NULL pointer dereference via a crafted matchinfo() query. | 5.5 |
2020-05-27 | CVE-2020-13631 | SQLite before 3.32.0 allows a virtual table to be renamed to the name of one of its shadow tables, related to alter.c and build.c. | 5.5 |
2018-02-08 | CVE-2017-6227 | A vulnerability in the IPv6 stack on Brocade Fibre Channel SAN products running Brocade Fabric OS (FOS) versions before 7.4.2b, 8.1.2 and 8.2.0 could allow an attacker to cause a denial of service (CPU consumption and device hang) condition by sending crafted Router Advertisement (RA) messages to a targeted system. | 6.5 |
2018-02-08 | CVE-2017-6225 | Cross-site Scripting vulnerability in multiple products Cross-site scripting (XSS) vulnerability in the web-based management interface of Brocade Fibre Channel SAN products running Brocade Fabric OS (FOS) versions before 7.4.2b, 8.1.2 and 8.2.0 could allow remote attackers to execute arbitrary code or access sensitive browser-based information. | 6.1 |