Vulnerabilities > CVE-2024-9754 - Out-of-bounds Read vulnerability in Tungstenautomation Power PDF

047910
CVSS 3.3 - LOW
Attack vector
LOCAL
Attack complexity
LOW
Privileges required
NONE
Confidentiality impact
LOW
Integrity impact
NONE
Availability impact
NONE
local
low complexity
tungstenautomation
CWE-125

Summary

Tungsten Automation Power PDF PDF File Parsing Out-Of-Bounds Read Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Tungsten Automation Power PDF. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of PDF files. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated object. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the current process. Was ZDI-CAN-24471.

Vulnerable Configurations

Part Description Count
Application
Tungstenautomation
1

Common Weakness Enumeration (CWE)

Common Attack Pattern Enumeration and Classification (CAPEC)

  • Overread Buffers
    An adversary attacks a target by providing input that causes an application to read beyond the boundary of a defined buffer. This typically occurs when a value influencing where to start or stop reading is set to reflect positions outside of the valid memory location of the buffer. This type of attack may result in exposure of sensitive information, a system crash, or arbitrary code execution.