Vulnerabilities > CVE-2023-30757 - Unspecified vulnerability in Siemens Totally Integrated Automation Portal

047910
CVSS 5.5 - MEDIUM
Attack vector
LOCAL
Attack complexity
LOW
Privileges required
LOW
Confidentiality impact
HIGH
Integrity impact
NONE
Availability impact
NONE
local
low complexity
siemens

Summary

A vulnerability has been identified in Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation Portal (TIA Portal) V19 (All versions). The know-how protection feature in affected products does not properly update the encryption of existing program blocks when a project file is updated. This could allow attackers with access to the project file to recover previous - yet unprotected - versions of the project without the knowledge of the know-how protection password.