Vulnerabilities > CVE-2022-3007 - Missing Authorization vulnerability in Syska Sw100 Smartwatch Firmware 2.0

047910
CVSS 8.1 - HIGH
Attack vector
ADJACENT_NETWORK
Attack complexity
LOW
Privileges required
NONE
Confidentiality impact
NONE
Integrity impact
HIGH
Availability impact
HIGH
low complexity
syska
CWE-862

Summary

The vulnerability exists in Syska SW100 Smartwatch due to an improper implementation and/or configuration of Nordic Device Firmware Update (DFU) which is used for performing Over-The-Air (OTA) firmware updates on the Bluetooth Low Energy (BLE) devices. An unauthenticated attacker could exploit this vulnerability by setting arbitrary values to handle on the vulnerable device over Bluetooth. Successful exploitation of this vulnerability could allow the attacker to perform firmware update, device reboot or data manipulation on the target device.

Vulnerable Configurations

Part Description Count
OS
Syska
2
Hardware
Syska
1

Common Weakness Enumeration (CWE)