Vulnerabilities > CVE-2021-31881 - Out-of-bounds Read vulnerability in Siemens products
Attack vector
NETWORK Attack complexity
LOW Privileges required
NONE Confidentiality impact
NONE Integrity impact
NONE Availability impact
HIGH Summary
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303). When processing a DHCP OFFER message, the DHCP client application does not validate the length of the Vendor option(s), leading to Denial-of-Service conditions. (FSMD-2021-0008)
Vulnerable Configurations
Part | Description | Count |
---|---|---|
Application | 4 | |
OS | 6 | |
Hardware | 6 |
Common Weakness Enumeration (CWE)
Common Attack Pattern Enumeration and Classification (CAPEC)
- Overread Buffers An adversary attacks a target by providing input that causes an application to read beyond the boundary of a defined buffer. This typically occurs when a value influencing where to start or stop reading is set to reflect positions outside of the valid memory location of the buffer. This type of attack may result in exposure of sensitive information, a system crash, or arbitrary code execution.
References
- https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf
- https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf
- https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf
- https://cert-portal.siemens.com/productcert/html/ssa-114589.html
- https://cert-portal.siemens.com/productcert/html/ssa-044112.html
- https://cert-portal.siemens.com/productcert/html/ssa-620288.html