Vulnerabilities > CVE-2021-31345 - Improper Validation of Specified Quantity in Input vulnerability in Siemens products

047910
CVSS 9.1 - CRITICAL
Attack vector
NETWORK
Attack complexity
LOW
Privileges required
NONE
Confidentiality impact
HIGH
Integrity impact
NONE
Availability impact
HIGH
network
low complexity
siemens
CWE-1284
critical

Summary

A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), PLUSCONTROL 1st Gen (All versions). The total length of an UDP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on a user-defined applications that runs on top of the UDP protocol. (FSMD-2021-0006)