Vulnerabilities > CVE-2020-3311 - Open Redirect vulnerability in Cisco Firepower Management Center

047910
CVSS 5.8 - MEDIUM
Attack vector
NETWORK
Attack complexity
MEDIUM
Privileges required
NONE
Confidentiality impact
PARTIAL
Integrity impact
PARTIAL
Availability impact
NONE
network
cisco
CWE-601
nessus

Summary

A vulnerability in the web interface of Cisco Firepower Management Center (FMC) Software could allow an unauthenticated, remote attacker to redirect a user to a malicious web page. The vulnerability is due to improper input validation of HTTP request parameters. An attacker could exploit this vulnerability by intercepting and modifying an HTTP request from a user. A successful exploit could allow the attacker to redirect the user to a specific malicious web page.

Vulnerable Configurations

Part Description Count
Application
Cisco
104

Common Attack Pattern Enumeration and Classification (CAPEC)

  • Fake the Source of Data
    An adversary provides data under a falsified identity. The purpose of using the falsified identity may be to prevent traceability of the provided data or it might be an attempt by the adversary to assume the rights granted to another identity. One of the simplest forms of this attack would be the creation of an email message with a modified "From" field in order to appear that the message was sent from someone other than the actual sender. Results of the attack vary depending on the details of the attack, but common results include privilege escalation, obfuscation of other attacks, and data corruption/manipulation.

Nessus

NASL familyCISCO
NASL idCISCO-SA-FMC-WEBREDIRECT-TCFGD42Y.NASL
descriptionAccording to its self-reported version, Cisco Firepower Management Center is affected by a vulnerability in its web interface due to improper input validation of HTTP request parameters. An unauthenticated, remote attacker can exploit this, by intercepting and modifying an HTTP request from a user, in order to redirect a user to a malicious web page. Please see the included Cisco BIDs and Cisco Security Advisory for more information.
last seen2020-05-21
modified2020-05-15
plugin id136621
published2020-05-15
reporterThis script is Copyright (C) 2020 and is owned by Tenable, Inc. or an Affiliate thereof.
sourcehttps://www.tenable.com/plugins/nessus/136621
titleCisco Firepower Management Center Open Redirect (cisco-sa-fmc-webredirect-TcFgd42y)
code
#
# (C) Tenable Network Security, Inc.
#

include('compat.inc');

if (description)
{
  script_id(136621);
  script_version("1.2");
  script_set_attribute(attribute:"plugin_modification_date", value:"2020/05/18");

  script_cve_id("CVE-2020-3311");
  script_xref(name:"CISCO-BUG-ID", value:"CSCvh03964");
  script_xref(name:"CISCO-SA", value:"cisco-sa-fmc-webredirect-TcFgd42y");
  script_xref(name:"IAVA", value:"2020-A-0206");

  script_name(english:"Cisco Firepower Management Center Open Redirect (cisco-sa-fmc-webredirect-TcFgd42y)");

  script_set_attribute(attribute:"synopsis", value:
"The remote device is missing a vendor-supplied security patch");
  script_set_attribute(attribute:"description", value:
"According to its self-reported version, Cisco Firepower Management Center is affected by a vulnerability in its web
interface due to improper input validation of HTTP request parameters. An unauthenticated, remote attacker can exploit
this, by intercepting and modifying an HTTP request from a user, in order to redirect a user to a malicious web page.

Please see the included Cisco BIDs and Cisco Security Advisory for more information.");
  # https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-fmc-webredirect-TcFgd42y
  script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?b54e5779");
  script_set_attribute(attribute:"see_also", value:"https://bst.cloudapps.cisco.com/bugsearch/bug/CSCvh03964");
  script_set_attribute(attribute:"solution", value:
"Upgrade to the relevant fixed version referenced in Cisco bug ID CSCvh03964");
  script_set_cvss_base_vector("CVSS2#AV:N/AC:M/Au:N/C:P/I:P/A:N");
  script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
  script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2020-3311");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_cwe_id(601);

  script_set_attribute(attribute:"vuln_publication_date", value:"2020/05/06");
  script_set_attribute(attribute:"patch_publication_date", value:"2020/05/06");
  script_set_attribute(attribute:"plugin_publication_date", value:"2020/05/15");

  script_set_attribute(attribute:"plugin_type", value:"local");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:cisco:firepower_management_center");
  script_set_attribute(attribute:"stig_severity", value:"I");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"CISCO");

  script_copyright(english:"This script is Copyright (C) 2020 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("cisco_firepower_version.nasl");
  script_require_keys("Host/Cisco/firepower_mc/version");

  exit(0);
}

include('vcf.inc');

app_info = vcf::get_app_info(app:'Cisco Firepower Management Center', kb_ver:'Host/Cisco/firepower_mc/version');

constraints = [{'fixed_version': '6.3.0'}];

vcf::check_version_and_report(
  app_info:app_info,
  constraints:constraints,
  severity:SECURITY_WARNING
);