Vulnerabilities > CVE-2020-12005 - Unrestricted Upload of File with Dangerous Type vulnerability in Rockwellautomation Factorytalk Linx and Rslinx Classic

047910
CVSS 7.5 - HIGH
Attack vector
NETWORK
Attack complexity
LOW
Privileges required
NONE
Confidentiality impact
NONE
Integrity impact
NONE
Availability impact
HIGH
network
low complexity
rockwellautomation
CWE-434

Summary

FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. A vulnerability exists in the communication function that enables users to upload EDS files by FactoryTalk Linx. This may allow an attacker to upload a file with bad compression, consuming all the available CPU resources, leading to a denial-of-service condition.

Common Attack Pattern Enumeration and Classification (CAPEC)

  • Accessing Functionality Not Properly Constrained by ACLs
    In applications, particularly web applications, access to functionality is mitigated by the authorization framework, whose job it is to map ACLs to elements of the application's functionality; particularly URL's for web apps. In the case that the administrator failed to specify an ACL for a particular element, an attacker may be able to access it with impunity. An attacker with the ability to access functionality not properly constrained by ACLs can obtain sensitive information and possibly compromise the entire application. Such an attacker can access resources that must be available only to users at a higher privilege level, can access management sections of the application or can run queries for data that he is otherwise not supposed to.
  • Privilege Abuse
    An adversary is able to exploit features of the target that should be reserved for privileged users or administrators but are exposed to use by lower or non-privileged accounts. Access to sensitive information and functionality must be controlled to ensure that only authorized users are able to access these resources. If access control mechanisms are absent or misconfigured, a user may be able to access resources that are intended only for higher level users. An adversary may be able to exploit this to utilize a less trusted account to gain information and perform activities reserved for more trusted accounts. This attack differs from privilege escalation and other privilege stealing attacks in that the adversary never actually escalates their privileges but instead is able to use a lesser degree of privilege to access resources that should be (but are not) reserved for higher privilege accounts. Likewise, the adversary does not exploit trust or subvert systems - all control functionality is working as configured but the configuration does not adequately protect sensitive resources at an appropriate level.