Vulnerabilities > CVE-2020-10052 - Information Exposure Through Log Files vulnerability in Siemens Simatic Rtls Locating Manager 2.10/2.10.2/2.9.3
Attack vector
LOCAL Attack complexity
LOW Privileges required
LOW Confidentiality impact
HIGH Integrity impact
NONE Availability impact
NONE Summary
A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions < V2.12). The affected application writes sensitive data, such as usernames and passwords in log files. A local attacker with access to the log files could use this information to launch further attacks.
Vulnerable Configurations
Part | Description | Count |
---|---|---|
Application | 3 |
Common Weakness Enumeration (CWE)
Common Attack Pattern Enumeration and Classification (CAPEC)
- Fuzzing and observing application log data/errors for application mapping An attacker sends random, malformed, or otherwise unexpected messages to a target application and observes the application's log or error messages returned. Fuzzing techniques involve sending random or malformed messages to a target and monitoring the target's response. The attacker does not initially know how a target will respond to individual messages but by attempting a large number of message variants they may find a variant that trigger's desired behavior. In this attack, the purpose of the fuzzing is to observe the application's log and error messages, although fuzzing a target can also sometimes cause the target to enter an unstable state, causing a crash. By observing logs and error messages, the attacker can learn details about the configuration of the target application and might be able to cause the target to disclose sensitive information.