code | #
# (C) Tenable Network Security, Inc.
#
include('compat.inc');
if (description)
{
script_id(127121);
script_version("1.4");
script_cvs_date("Date: 2019/10/18 23:14:14");
script_cve_id("CVE-2019-1930", "CVE-2019-1931");
script_bugtraq_id(109047);
script_xref(name:"CISCO-BUG-ID", value:"CSCvo90805");
script_xref(name:"CISCO-BUG-ID", value:"CSCvo92913");
script_xref(name:"CISCO-SA", value:"cisco-sa-20190703-fmc-xss");
script_name(english:"Cisco Firepower Management Center 6.2.3.x < 6.2.3.14 / 6.3.0.x < 6.3.0.4 / 6.4.0.x < 6.4.0.2 XSS (cisco-sa-20190703-fmc-xss)");
script_summary(english:"Checks the version of Cisco Firepower Management Center");
script_set_attribute(attribute:"synopsis", value:
"The remote device is missing a vendor-supplied security patch");
script_set_attribute(attribute:"description", value:
"According to its self-reported version, Cisco Firepower Management Center is affected by multiple vulnerabilities.
Please see the included Cisco BIDs and Cisco Security Advisory for more information");
# http://tools.cisco.com/security/center/content/CiscoAppliedMitigationBulletin/cisco-amb-20060922-understanding-xss
script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?1596bcb6");
# https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190703-fmc-xss
script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?3fd431fb");
script_set_attribute(attribute:"see_also", value:"https://bst.cloudapps.cisco.com/bugsearch/bug/CSCvo90805");
script_set_attribute(attribute:"see_also", value:"https://bst.cloudapps.cisco.com/bugsearch/bug/CSCvo92913");
script_set_attribute(attribute:"solution", value:
"Upgrade to the relevant fixed version referenced in Cisco bug IDs CSCvo90805, CSCvo92913");
script_set_cvss_base_vector("CVSS2#AV:N/AC:M/Au:N/C:N/I:P/A:N");
script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N");
script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
script_set_attribute(attribute:"cvss_score_source", value:"CVE-2019-1930");
script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
script_cwe_id(79);
script_set_attribute(attribute:"vuln_publication_date", value:"2019/07/03");
script_set_attribute(attribute:"patch_publication_date", value:"2019/07/03");
script_set_attribute(attribute:"plugin_publication_date", value:"2019/08/05");
script_set_attribute(attribute:"plugin_type", value:"local");
script_set_attribute(attribute:"cpe", value:"cpe:/o:cisco:firepower_management_center");
script_end_attributes();
script_category(ACT_GATHER_INFO);
script_family(english:"CISCO");
script_copyright(english:"This script is Copyright (C) 2019 and is owned by Tenable, Inc. or an Affiliate thereof.");
script_dependencies("cisco_firepower_version.nasl");
script_require_keys("Host/Cisco/firepower_mc/version");
exit(0);
}
include('vcf.inc');
app_info = vcf::get_app_info(app:'Cisco Firepower Management Center', kb_ver:'Host/Cisco/firepower_mc/version');
vcf::check_granularity(app_info:app_info, sig_segments:3);
constraints = [
{'min_version': '6.2.3', 'fixed_version': '6.2.3.14'},
{'min_version': '6.3.0', 'fixed_version': '6.3.0.4'},
{'min_version': '6.4.0', 'fixed_version': '6.4.0.2'}
];
vcf::check_version_and_report(
app_info:app_info,
constraints:constraints,
severity:SECURITY_WARNING,
flags:{'xss': TRUE}
);
|