Vulnerabilities > CVE-2018-10598 - Out-of-bounds Read vulnerability in Deltaww Cncsoft and Screeneditor

047910
CVSS 8.1 - HIGH
Attack vector
NETWORK
Attack complexity
LOW
Privileges required
NONE
Confidentiality impact
HIGH
Integrity impact
NONE
Availability impact
HIGH
network
low complexity
deltaww
CWE-125

Summary

CNCSoft Version 1.00.83 and prior with ScreenEditor Version 1.00.54 has two out-of-bounds read vulnerabilities could cause the software to crash due to lacking user input validation for processing project files. Which may allow an attacker to gain remote code execution with administrator privileges if exploited.

Vulnerable Configurations

Part Description Count
Application
Deltaww
2

Common Weakness Enumeration (CWE)

Common Attack Pattern Enumeration and Classification (CAPEC)

  • Overread Buffers
    An adversary attacks a target by providing input that causes an application to read beyond the boundary of a defined buffer. This typically occurs when a value influencing where to start or stop reading is set to reflect positions outside of the valid memory location of the buffer. This type of attack may result in exposure of sensitive information, a system crash, or arbitrary code execution.