Vulnerabilities > CVE-2017-8958 - Unspecified vulnerability in HP Intelligent Management Center

047910
CVSS 8.8 - HIGH
Attack vector
NETWORK
Attack complexity
LOW
Privileges required
NONE
Confidentiality impact
HIGH
Integrity impact
HIGH
Availability impact
HIGH
network
low complexity
hp
nessus

Summary

A Remote Code Execution vulnerability in HPE Intelligent Management Center (iMC) PLAT version 7.3 E0504P04 and earlier was found.

Nessus

NASL familyMisc.
NASL idHP_IMC_73_E0506P04.NASL
descriptionThe version of HPE Intelligent Management Center (iMC) PLAT installed on the remote host is prior to 7.3 E0506P03. It is, therefore, affected by multiple remote code execution vulnerabilities. Note that Intelligent Management Center (iMC) is an HPE product; however, it is branded as H3C.
last seen2020-06-01
modified2020-06-02
plugin id103788
published2017-10-11
reporterThis script is Copyright (C) 2017-2018 Tenable Network Security, Inc.
sourcehttps://www.tenable.com/plugins/nessus/103788
titleH3C / HPE Intelligent Management Center PLAT < 7.3 E0506P03 Multiple RCE
code
#
# (C) Tenable Network Security, Inc.
#

include("compat.inc");

if (description)
{
  script_id(103788);
  script_version("1.5");
  script_cvs_date("Date: 2018/11/15 20:50:23");

  script_cve_id(
   "CVE-2017-8958",
   "CVE-2017-8967",
   "CVE-2017-8962",
   "CVE-2017-8963",
   "CVE-2017-8964",
   "CVE-2017-8965",
   "CVE-2017-8966",
   "CVE-2017-8961"
  );
  script_bugtraq_id(101202);

  script_xref(name:"HP", value:"emr_na-hpesbhf03786en_us");
  script_xref(name:"HP", value:"HPESBHF03786");
  script_xref(name:"HP", value:"emr_na-hpesbhf03787en_us");
  script_xref(name:"HP", value:"HPESBHF03787");
  script_xref(name:"HP", value:"emr_na-hpesbhf03788en_us");
  script_xref(name:"HP", value:"HPESBHF03788");


  script_name(english:"H3C / HPE Intelligent Management Center PLAT < 7.3 E0506P03 Multiple RCE");
  script_summary(english:"Checks the version of HPE Intelligent Management Center.");

  script_set_attribute(attribute:"synopsis", value:
"An application installed on the remote Windows host is affected by
a remote code execution vulnerability.");
  script_set_attribute(attribute:"description", value:
"The version of HPE Intelligent Management Center (iMC) PLAT installed
on the remote host is prior to 7.3 E0506P03. It is, therefore,
affected by multiple remote code execution vulnerabilities.

Note that Intelligent Management Center (iMC) is an HPE product;
however, it is branded as H3C.");
  # https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-hpesbhf03786en_us
  script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?921e68d0");
  # https://support.hpe.com/hpsc/doc/public/display?docId=hpesbhf03787en_us
  script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?76d7a548");
  # https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-hpesbhf03788en_us
  script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?da943b3d");
  script_set_attribute(attribute:"solution", value:
"Upgrade to H3C / HPE iMC version 7.3 E0506P03 or later.");
  script_set_cvss_base_vector("CVSS2#AV:N/AC:M/Au:N/C:C/I:C/A:C");
  script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
  script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_set_attribute(attribute:"exploit_available", value:"false");

  script_set_attribute(attribute:"vuln_publication_date", value:"2017/10/05");
  script_set_attribute(attribute:"patch_publication_date", value:"2017/10/05");
  script_set_attribute(attribute:"plugin_publication_date", value:"2017/10/11");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/a:hp:intelligent_management_center");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Misc.");

  script_copyright(english:"This script is Copyright (C) 2017-2018 Tenable Network Security, Inc.");

  script_dependencies('hp_imc_detect.nbin');
  script_require_ports('Services/activemq', 61616);

  exit(0);
}

include("audit.inc");
include("global_settings.inc");
include("misc_func.inc");

# Figure out which port to use
port = get_service(svc:'activemq', default:61616, exit_on_fail:TRUE);
version = get_kb_item_or_exit('hp/hp_imc/'+port+'/version');

app = 'HP Intelligent Management Center';

fixed_display = '7.3-E0506P03';

fix = "7.3";
patchfix = NULL;

# check patch version if 7.3
if (version =~ "^7.[0-3]\-")
{
  # Versions < 7.3 E0506, remove letters and dashes in version
  patch = pregmatch(pattern:"[0-9.]+-E([0-9A-Z]+)", string:version);
  if (!patch) audit(AUDIT_UNKNOWN_APP_VER, app);
  patchver = ereg_replace(string:patch[1], pattern:"[A-Z\-]", replace:".");
  if (!patchver) audit(AUDIT_UNKNOWN_APP_VER, app);

  patchfix = "0506.03";
}

# if pre 7.3 or 7.3 with patchver before 0506
if ((ver_compare(ver:version, fix:fix, strict:FALSE) < 0) ||
    (!isnull(patchfix) && ver_compare(ver:patchver, fix:patchfix, strict:FALSE) < 0))
{
  items = make_array(
    "Installed version", version,
    "Fixed version", fixed_display
  );

  order = make_list("Installed version", "Fixed version");
  report = report_items_str(report_items:items, ordered_fields:order);

  security_report_v4(port:port, extra:report, severity:SECURITY_HOLE);
  exit(0);
}
else
  audit(AUDIT_INST_VER_NOT_VULN, app, version);