Vulnerabilities > CVE-2023-27595 - Improper Handling of Exceptional Conditions vulnerability in Cilium 1.13.0

047910
CVSS 9.8 - CRITICAL
Attack vector
NETWORK
Attack complexity
LOW
Privileges required
NONE
Confidentiality impact
HIGH
Integrity impact
HIGH
Availability impact
HIGH
network
low complexity
cilium
CWE-755
critical

Summary

Cilium is a networking, observability, and security solution with an eBPF-based dataplane. In version 1.13.0, when Cilium is started, there is a short period when Cilium eBPF programs are not attached to the host. During this period, the host does not implement any of Cilium's featureset. This can cause disruption to newly established connections during this period due to the lack of Load Balancing, or can cause Network Policy bypass due to the lack of Network Policy enforcement during the window. This vulnerability impacts any Cilium-managed endpoints on the node (such as Kubernetes Pods), as well as the host network namespace (including Host Firewall). This vulnerability is fixed in Cilium 1.13.1 or later. Cilium releases 1.12.x, 1.11.x, and earlier are not affected. There are no known workarounds.

Vulnerable Configurations

Part Description Count
Application
Cilium
1