Vulnerabilities > CVE-2014-2643 - Remote Privilege Escalation vulnerability in HP Systems Insight Manager

047910
CVSS 6.5 - MEDIUM
Attack vector
NETWORK
Attack complexity
LOW
Privileges required
SINGLE
Confidentiality impact
PARTIAL
Integrity impact
PARTIAL
Availability impact
PARTIAL
network
low complexity
hp
nessus

Summary

Unspecified vulnerability in HP Systems Insight Manager (SIM) before 7.4 allows remote authenticated users to gain privileges via unknown vectors.

Nessus

NASL familyWindows
NASL idHP_SYSTEMS_INSIGHT_MANAGER_74_MULTIPLE_VULNS.NASL
descriptionThe version of HP Systems Insight Manager installed on the remote Windows host is affected by the following vulnerabilities : - An unspecified vulnerability exists that allows a remote authenticated attacker to gain limited elevated privileges. (CVE-2014-2643) - A vulnerability exists that allows reflected cross-site scripting attacks, due to the improper validation of user-supplied input before it is returned to the users. Using a specially crafted request, a remote attacker can execute arbitrary script code within a user
last seen2020-06-01
modified2020-06-02
plugin id78079
published2014-10-07
reporterThis script is Copyright (C) 2014-2019 and is owned by Tenable, Inc. or an Affiliate thereof.
sourcehttps://www.tenable.com/plugins/nessus/78079
titleHP Systems Insight Manager < 7.4 Multiple Vulnerabilities
code
#
# (C) Tenable Network Security, Inc.
#

include("compat.inc");

if (description)
{
  script_id(78079);
  script_version("1.8");
  script_cvs_date("Date: 2019/11/25");

  script_cve_id("CVE-2014-2643", "CVE-2014-2644", "CVE-2014-2645");
  script_bugtraq_id(70223, 70224, 70225);
  script_xref(name:"HP", value:"emr_na-c04468121");
  script_xref(name:"HP", value:"HPSBMU03118");
  script_xref(name:"HP", value:"SSRT101715");

  script_name(english:"HP Systems Insight Manager < 7.4 Multiple Vulnerabilities");
  script_summary(english:"Checks the version of HP Systems Insight Manager.");

  script_set_attribute(attribute:"synopsis", value:
"The remote Windows host contains software that is affected by multiple
vulnerabilities.");
  script_set_attribute(attribute:"description", value:
"The version of HP Systems Insight Manager installed on the remote
Windows host is affected by the following vulnerabilities :

  - An unspecified vulnerability exists that allows a remote
    authenticated attacker to gain limited elevated
    privileges. (CVE-2014-2643)

  - A vulnerability exists that allows reflected cross-site
    scripting attacks, due to the improper validation of
    user-supplied input before it is returned to the users.
    Using a specially crafted request, a remote attacker can
    execute arbitrary script code within a user's browser.
    (CVE-2014-2644)

  - An unspecified flaw exists that allows a remote attacker
    to conduct a clickjacking attack. (CVE-2014-2645)");
  # https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-c04468121
  script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?88eef9a4");
  script_set_attribute(attribute:"see_also", value:"https://www.securityfocus.com/archive/1/533606/30/0/threaded");
  script_set_attribute(attribute:"see_also", value:"https://www.securityfocus.com/archive/1/533635/30/0/threaded");
  script_set_attribute(attribute:"solution", value:
"Upgrade to HP Systems Insight Manager 7.4 or later. A hotfix has also
been made available for HP Systems Insight Manager 7.2.");
  script_set_cvss_base_vector("CVSS2#AV:N/AC:L/Au:S/C:P/I:P/A:P");
  script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2014-2643");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_set_attribute(attribute:"exploit_available", value:"false");
  script_cwe_id(20, 74, 79, 442, 629, 711, 712, 722, 725, 750, 751, 800, 801, 809, 811, 864, 900, 928, 931, 990);

  script_set_attribute(attribute:"vuln_publication_date", value:"2012/10/02");
  script_set_attribute(attribute:"patch_publication_date", value:"2014/10/02");
  script_set_attribute(attribute:"plugin_publication_date", value:"2014/10/07");

  script_set_attribute(attribute:"plugin_type", value:"local");
  script_set_attribute(attribute:"cpe", value:"cpe:/a:hp:systems_insight_manager");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Windows");

  script_copyright(english:"This script is Copyright (C) 2014-2019 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("hp_systems_insight_manager_installed.nasl");
  script_require_keys("installed_sw/HP Systems Insight Manager");

  exit(0);
}

include("audit.inc");
include("global_settings.inc");
include("install_func.inc");
include("misc_func.inc");

app_name = "HP Systems Insight Manager";
report   = NULL;

install = get_single_install(app_name:app_name);
path    = install['path'];
version = install['version'];

# A hotfix is available for 7.2
if (version =~ '^(([A-C]\\.)?07\\.02\\.[0-9\\.]+)')
{
  hotfixes = install['Hotfixes'];
  if (empty_or_null(hotfixes)) hotfixes = 'None';
  else hotfixes = str_replace(string:hotfixes, find:";", replace:", ");

  fixed_hotfix = 'HOTFIX72_038';
  if (fixed_hotfix >!< hotfixes)
    report =
      '\n  Path               : ' + path +
      '\n  Installed version  : ' + version +
      '\n  Installed hotfixes : ' + hotfixes +
      '\n  Fixed hotfix       : ' + fixed_hotfix + '\n';
}
else if (version =~ '^(([A-Z]\\.)?0[0-6]\\.|([A-C]\\.)?07\\.0[0-3]\\.[0-9\\.]+)')
{
  report =
    '\n  Path              : ' + path +
    '\n  Installed version : ' + version +
    '\n  Fixed version     : C.07.04.00.00\n';
}

if (!isnull(report))
{
  port = get_kb_item('SMB/transport');
  if (!port) port = 445;

  set_kb_item(name:'www/'+port+'/XSS', value:TRUE);

  if (report_verbosity > 0) security_warning(port:port, extra:report);
  else security_warning(port);
}
else audit(AUDIT_INST_PATH_NOT_VULN, app_name, version, path);