Vulnerabilities > CVE-2009-3840 - Denial of Service vulnerability in HP OpenView Network Node Manager 'ovdbrun.exe'
Attack vector
NETWORK Attack complexity
LOW Privileges required
NONE Confidentiality impact
NONE Integrity impact
NONE Availability impact
PARTIAL Summary
The embedded database engine service (aka ovdbrun.exe) in HP OpenView Network Node Manager (OV NNM) 7.51 and 7.53 allows remote attackers to cause a denial of service (daemon crash) via an invalid Error Code field in a packet.
Vulnerable Configurations
Part | Description | Count |
---|---|---|
Application | 8 |
Exploit-Db
description HP Openview NNM 7.53 Invalid DB Error Code Vulnerability. CVE-2009-3840. Dos exploit for windows platform id EDB-ID:10176 last seen 2016-02-01 modified 2009-11-17 published 2009-11-17 reporter Core Security source https://www.exploit-db.com/download/10176/ title HP Openview NNM 7.53 Invalid DB Error Code Vulnerability description IBM SolidDB invalid error code vulnerability. CVE-2009-3840. Dos exploit for windows platform id EDB-ID:10377 last seen 2016-02-01 modified 2009-11-18 published 2009-11-18 reporter Core Security source https://www.exploit-db.com/download/10377/ title IBM SolidDB - Invalid Error Code Vulnerability
Nessus
NASL family HP-UX Local Security Checks NASL id HPUX_PHSS_38488.NASL description s700_800 11.X OV NNM7.53 PA-RISC Intermediate Patch 20 : The remote HP-UX host is affected by multiple vulnerabilities : - Potential vulnerabilities have been identified with HP OpenView Network Node Manager (OV NNM). The vulnerabilities could be exploited remotely to execute arbitrary code with administrator priviliges or to create a Denial of Service (DoS). (HPSBMA02477 SSRT090177) - A potential vulnerability has been identified with HP OpenView Network Node Manager (OV NNM). The vulnerability could be exploited remotely to execute arbitrary code or to create a Denial of Service (DoS). (HPSBMA02348 SSRT080033) - A potential security vulnerability has been identified with HP OpenView Network Node Manager (OV NNM). The vulnerability could be exploited remotely to create a Denial of Service (DoS). (HPSBMA02374 SSRT080046) - Potential vulnerabilities have been identified with HP OpenView Network Node Manager (OV NNM). The vulnerabilities could be exploited remotely to create a Denial of Service (DoS) or to execute arbitrary code. References: CVE-2008-3536, CVE-2008-3537, CVE-2008-3544 (Bugtraq ID 28668). (HPSBMA02362 SSRT080044, SSRT080045, SSRT080042) - A potential vulnerability has been identified with HP OpenView Network Node Manager (OV NNM). The vulnerability could be exploited remotely execute arbitrary code or to create a Denial of Service (DoS). (HPSBMA02338 SSRT080024, SSRT080041) last seen 2020-06-01 modified 2020-06-02 plugin id 39379 published 2009-06-15 reporter This script is Copyright (C) 2009-2018 Tenable Network Security, Inc. source https://www.tenable.com/plugins/nessus/39379 title HP-UX PHSS_38488 : s700_800 11.X OV NNM7.53 PA-RISC Intermediate Patch 20 code # # (C) Tenable Network Security, Inc. # # The descriptive text and patch checks in this plugin were # extracted from HP patch PHSS_38488. The text itself is # copyright (C) Hewlett-Packard Development Company, L.P. # if (NASL_LEVEL < 3000) exit(0); include("compat.inc"); if (description) { script_id(39379); script_version("1.22"); script_cvs_date("Date: 2018/08/10 18:07:07"); script_cve_id("CVE-2008-1697", "CVE-2008-1842", "CVE-2008-3536", "CVE-2008-3537", "CVE-2008-3544", "CVE-2008-3545", "CVE-2009-3840", "CVE-2010-2710"); script_xref(name:"HP", value:"emr_na-c01466051"); script_xref(name:"HP", value:"emr_na-c01495949"); script_xref(name:"HP", value:"emr_na-c01537275"); script_xref(name:"HP", value:"emr_na-c01567813"); script_xref(name:"HP", value:"emr_na-c01926980"); script_xref(name:"HP", value:"SSRT080024"); script_xref(name:"HP", value:"SSRT080033"); script_xref(name:"HP", value:"SSRT080041"); script_xref(name:"HP", value:"SSRT080042"); script_xref(name:"HP", value:"SSRT080044"); script_xref(name:"HP", value:"SSRT080045"); script_xref(name:"HP", value:"SSRT080046"); script_xref(name:"HP", value:"SSRT090177"); script_name(english:"HP-UX PHSS_38488 : s700_800 11.X OV NNM7.53 PA-RISC Intermediate Patch 20"); script_summary(english:"Checks for the patch in the swlist output"); script_set_attribute( attribute:"synopsis", value:"The remote HP-UX host is missing a security-related patch." ); script_set_attribute( attribute:"description", value: "s700_800 11.X OV NNM7.53 PA-RISC Intermediate Patch 20 : The remote HP-UX host is affected by multiple vulnerabilities : - Potential vulnerabilities have been identified with HP OpenView Network Node Manager (OV NNM). The vulnerabilities could be exploited remotely to execute arbitrary code with administrator priviliges or to create a Denial of Service (DoS). (HPSBMA02477 SSRT090177) - A potential vulnerability has been identified with HP OpenView Network Node Manager (OV NNM). The vulnerability could be exploited remotely to execute arbitrary code or to create a Denial of Service (DoS). (HPSBMA02348 SSRT080033) - A potential security vulnerability has been identified with HP OpenView Network Node Manager (OV NNM). The vulnerability could be exploited remotely to create a Denial of Service (DoS). (HPSBMA02374 SSRT080046) - Potential vulnerabilities have been identified with HP OpenView Network Node Manager (OV NNM). The vulnerabilities could be exploited remotely to create a Denial of Service (DoS) or to execute arbitrary code. References: CVE-2008-3536, CVE-2008-3537, CVE-2008-3544 (Bugtraq ID 28668). (HPSBMA02362 SSRT080044, SSRT080045, SSRT080042) - A potential vulnerability has been identified with HP OpenView Network Node Manager (OV NNM). The vulnerability could be exploited remotely execute arbitrary code or to create a Denial of Service (DoS). (HPSBMA02338 SSRT080024, SSRT080041)" ); # http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?objectID=c01466051 script_set_attribute( attribute:"see_also", value:"http://www.nessus.org/u?202438e1" ); # http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?objectID=c01495949 script_set_attribute( attribute:"see_also", value:"http://www.nessus.org/u?6c4897f2" ); # http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?objectID=c01537275 script_set_attribute( attribute:"see_also", value:"http://www.nessus.org/u?cd8ebfb4" ); # http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?objectID=c01567813 script_set_attribute( attribute:"see_also", value:"http://www.nessus.org/u?39f46ac2" ); # http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?objectID=c01926980 script_set_attribute( attribute:"see_also", value:"http://www.nessus.org/u?499137a6" ); script_set_attribute( attribute:"solution", value:"Install patch PHSS_38488 or subsequent." ); script_set_cvss_base_vector("CVSS2#AV:N/AC:L/Au:N/C:C/I:C/A:C"); script_set_attribute(attribute:"exploitability_ease", value:"Exploits are available"); script_set_attribute(attribute:"exploit_available", value:"true"); script_set_attribute(attribute:"metasploit_name", value:'HP OpenView NNM 7.53, 7.51 OVAS.EXE Pre-Authentication Stack Buffer Overflow'); script_set_attribute(attribute:"exploit_framework_metasploit", value:"true"); script_set_attribute(attribute:"exploit_framework_canvas", value:"true"); script_set_attribute(attribute:"canvas_package", value:'D2ExploitPack'); script_cwe_id(119, 189); script_set_attribute(attribute:"plugin_type", value:"local"); script_set_attribute(attribute:"cpe", value:"cpe:/o:hp:hp-ux"); script_set_attribute(attribute:"patch_publication_date", value:"2008/09/24"); script_set_attribute(attribute:"patch_modification_date", value:"2008/10/08"); script_set_attribute(attribute:"plugin_publication_date", value:"2009/06/15"); script_end_attributes(); script_category(ACT_GATHER_INFO); script_copyright(english:"This script is Copyright (C) 2009-2018 Tenable Network Security, Inc."); script_family(english:"HP-UX Local Security Checks"); script_dependencies("ssh_get_info.nasl"); script_require_keys("Host/local_checks_enabled", "Host/HP-UX/version", "Host/HP-UX/swlist"); exit(0); } include("audit.inc"); include("global_settings.inc"); include("hpux.inc"); if (!get_kb_item("Host/local_checks_enabled")) audit(AUDIT_LOCAL_CHECKS_NOT_ENABLED); if (!get_kb_item("Host/HP-UX/version")) audit(AUDIT_OS_NOT, "HP-UX"); if (!get_kb_item("Host/HP-UX/swlist")) audit(AUDIT_PACKAGE_LIST_MISSING); if (!hpux_check_ctx(ctx:"11.11 11.23 11.31", proc:"parisc")) { exit(0, "The host is not affected since PHSS_38488 applies to a different OS release / architecture."); } patches = make_list("PHSS_38488", "PHSS_38782", "PHSS_39245", "PHSS_39639", "PHSS_39944", "PHSS_40374", "PHSS_40707", "PHSS_41242", "PHSS_41606", "PHSS_41857", "PHSS_42232", "PHSS_43046", "PHSS_43353"); foreach patch (patches) { if (hpux_installed(app:patch)) { exit(0, "The host is not affected because patch "+patch+" is installed."); } } flag = 0; if (hpux_check_patch(app:"OVNNMETCore.OVNNMET-CORE", version:"B.07.50.00")) flag++; if (hpux_check_patch(app:"OVNNMETCore.OVNNMET-IPV6", version:"B.07.50.00")) flag++; if (hpux_check_patch(app:"OVNNMETCore.OVNNMET-PESA", version:"B.07.50.00")) flag++; if (hpux_check_patch(app:"OVNNMgr.OVMIB-CONTRIB", version:"B.07.50.00")) flag++; if (hpux_check_patch(app:"OVNNMgr.OVNNM-RUN", version:"B.07.50.00")) flag++; if (hpux_check_patch(app:"OVNNMgr.OVNNMGR-JPN", version:"B.07.50.00")) flag++; if (hpux_check_patch(app:"OVNNMgr.OVNNMGR-KOR", version:"B.07.50.00")) flag++; if (hpux_check_patch(app:"OVNNMgr.OVNNMGR-SCH", version:"B.07.50.00")) flag++; if (hpux_check_patch(app:"OVNNMgr.OVWWW-JPN", version:"B.07.50.00")) flag++; if (hpux_check_patch(app:"OVNNMgr.OVWWW-KOR", version:"B.07.50.00")) flag++; if (hpux_check_patch(app:"OVNNMgr.OVWWW-SCH", version:"B.07.50.00")) flag++; if (hpux_check_patch(app:"OVNNMgrMan.OVNNM-RUN-MAN", version:"B.07.50.00")) flag++; if (hpux_check_patch(app:"OVNNMgrRtDOC.OVNNM-ENG-DOC", version:"B.07.50.00")) flag++; if (hpux_check_patch(app:"OVPlatform.OVDB-RUN", version:"B.07.50.00")) flag++; if (hpux_check_patch(app:"OVPlatform.OVEVENT-MIN", version:"B.07.50.00")) flag++; if (hpux_check_patch(app:"OVPlatform.OVMIN", version:"B.07.50.00")) flag++; if (hpux_check_patch(app:"OVPlatform.OVWIN", version:"B.07.50.00")) flag++; if (hpux_check_patch(app:"OVPlatform.OVWWW-EVNT", version:"B.07.50.00")) flag++; if (hpux_check_patch(app:"OVPlatform.OVWWW-FW", version:"B.07.50.00")) flag++; if (hpux_check_patch(app:"OVPlatform.OVWWW-SRV", version:"B.07.50.00")) flag++; if (flag) { if (report_verbosity > 0) security_hole(port:0, extra:hpux_report_get()); else security_hole(0); exit(0); } else audit(AUDIT_HOST_NOT, "affected");
NASL family HP-UX Local Security Checks NASL id HPUX_PHSS_38489.NASL description s700_800 11.X OV NNM7.53 IA-64 Intermediate Patch 20 : The remote HP-UX host is affected by multiple vulnerabilities : - Potential vulnerabilities have been identified with HP OpenView Network Node Manager (OV NNM). The vulnerabilities could be exploited remotely to create a Denial of Service (DoS) or to execute arbitrary code. References: CVE-2008-3536, CVE-2008-3537, CVE-2008-3544 (Bugtraq ID 28668). (HPSBMA02362 SSRT080044, SSRT080045, SSRT080042) - A potential vulnerability has been identified with HP OpenView Network Node Manager (OV NNM). The vulnerability could be exploited remotely execute arbitrary code or to create a Denial of Service (DoS). (HPSBMA02338 SSRT080024, SSRT080041) - A potential security vulnerability has been identified with HP OpenView Network Node Manager (OV NNM). The vulnerability could be exploited remotely to create a Denial of Service (DoS). (HPSBMA02374 SSRT080046) - Potential vulnerabilities have been identified with HP OpenView Network Node Manager (OV NNM). The vulnerabilities could be exploited remotely to execute arbitrary code with administrator priviliges or to create a Denial of Service (DoS). (HPSBMA02477 SSRT090177) - A potential vulnerability has been identified with HP OpenView Network Node Manager (OV NNM). The vulnerability could be exploited remotely to execute arbitrary code or to create a Denial of Service (DoS). (HPSBMA02348 SSRT080033) last seen 2020-06-01 modified 2020-06-02 plugin id 39380 published 2009-06-15 reporter This script is Copyright (C) 2009-2018 Tenable Network Security, Inc. source https://www.tenable.com/plugins/nessus/39380 title HP-UX PHSS_38489 : s700_800 11.X OV NNM7.53 IA-64 Intermediate Patch 20 code # # (C) Tenable Network Security, Inc. # # The descriptive text and patch checks in this plugin were # extracted from HP patch PHSS_38489. The text itself is # copyright (C) Hewlett-Packard Development Company, L.P. # if (NASL_LEVEL < 3000) exit(0); include("compat.inc"); if (description) { script_id(39380); script_version("1.22"); script_cvs_date("Date: 2018/08/10 18:07:07"); script_cve_id("CVE-2008-1697", "CVE-2008-1842", "CVE-2008-3536", "CVE-2008-3537", "CVE-2008-3544", "CVE-2008-3545", "CVE-2009-3840", "CVE-2010-2710"); script_xref(name:"HP", value:"emr_na-c01466051"); script_xref(name:"HP", value:"emr_na-c01495949"); script_xref(name:"HP", value:"emr_na-c01537275"); script_xref(name:"HP", value:"emr_na-c01567813"); script_xref(name:"HP", value:"emr_na-c01926980"); script_xref(name:"HP", value:"SSRT080024"); script_xref(name:"HP", value:"SSRT080033"); script_xref(name:"HP", value:"SSRT080041"); script_xref(name:"HP", value:"SSRT080042"); script_xref(name:"HP", value:"SSRT080044"); script_xref(name:"HP", value:"SSRT080045"); script_xref(name:"HP", value:"SSRT080046"); script_xref(name:"HP", value:"SSRT090177"); script_name(english:"HP-UX PHSS_38489 : s700_800 11.X OV NNM7.53 IA-64 Intermediate Patch 20"); script_summary(english:"Checks for the patch in the swlist output"); script_set_attribute( attribute:"synopsis", value:"The remote HP-UX host is missing a security-related patch." ); script_set_attribute( attribute:"description", value: "s700_800 11.X OV NNM7.53 IA-64 Intermediate Patch 20 : The remote HP-UX host is affected by multiple vulnerabilities : - Potential vulnerabilities have been identified with HP OpenView Network Node Manager (OV NNM). The vulnerabilities could be exploited remotely to create a Denial of Service (DoS) or to execute arbitrary code. References: CVE-2008-3536, CVE-2008-3537, CVE-2008-3544 (Bugtraq ID 28668). (HPSBMA02362 SSRT080044, SSRT080045, SSRT080042) - A potential vulnerability has been identified with HP OpenView Network Node Manager (OV NNM). The vulnerability could be exploited remotely execute arbitrary code or to create a Denial of Service (DoS). (HPSBMA02338 SSRT080024, SSRT080041) - A potential security vulnerability has been identified with HP OpenView Network Node Manager (OV NNM). The vulnerability could be exploited remotely to create a Denial of Service (DoS). (HPSBMA02374 SSRT080046) - Potential vulnerabilities have been identified with HP OpenView Network Node Manager (OV NNM). The vulnerabilities could be exploited remotely to execute arbitrary code with administrator priviliges or to create a Denial of Service (DoS). (HPSBMA02477 SSRT090177) - A potential vulnerability has been identified with HP OpenView Network Node Manager (OV NNM). The vulnerability could be exploited remotely to execute arbitrary code or to create a Denial of Service (DoS). (HPSBMA02348 SSRT080033)" ); # http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?objectID=c01466051 script_set_attribute( attribute:"see_also", value:"http://www.nessus.org/u?202438e1" ); # http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?objectID=c01495949 script_set_attribute( attribute:"see_also", value:"http://www.nessus.org/u?6c4897f2" ); # http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?objectID=c01537275 script_set_attribute( attribute:"see_also", value:"http://www.nessus.org/u?cd8ebfb4" ); # http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?objectID=c01567813 script_set_attribute( attribute:"see_also", value:"http://www.nessus.org/u?39f46ac2" ); # http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?objectID=c01926980 script_set_attribute( attribute:"see_also", value:"http://www.nessus.org/u?499137a6" ); script_set_attribute( attribute:"solution", value:"Install patch PHSS_38489 or subsequent." ); script_set_cvss_base_vector("CVSS2#AV:N/AC:L/Au:N/C:C/I:C/A:C"); script_set_attribute(attribute:"exploitability_ease", value:"Exploits are available"); script_set_attribute(attribute:"exploit_available", value:"true"); script_set_attribute(attribute:"metasploit_name", value:'HP OpenView NNM 7.53, 7.51 OVAS.EXE Pre-Authentication Stack Buffer Overflow'); script_set_attribute(attribute:"exploit_framework_metasploit", value:"true"); script_set_attribute(attribute:"exploit_framework_canvas", value:"true"); script_set_attribute(attribute:"canvas_package", value:'D2ExploitPack'); script_cwe_id(119, 189); script_set_attribute(attribute:"plugin_type", value:"local"); script_set_attribute(attribute:"cpe", value:"cpe:/o:hp:hp-ux"); script_set_attribute(attribute:"patch_publication_date", value:"2008/09/24"); script_set_attribute(attribute:"patch_modification_date", value:"2008/10/08"); script_set_attribute(attribute:"plugin_publication_date", value:"2009/06/15"); script_end_attributes(); script_category(ACT_GATHER_INFO); script_copyright(english:"This script is Copyright (C) 2009-2018 Tenable Network Security, Inc."); script_family(english:"HP-UX Local Security Checks"); script_dependencies("ssh_get_info.nasl"); script_require_keys("Host/local_checks_enabled", "Host/HP-UX/version", "Host/HP-UX/swlist"); exit(0); } include("audit.inc"); include("global_settings.inc"); include("hpux.inc"); if (!get_kb_item("Host/local_checks_enabled")) audit(AUDIT_LOCAL_CHECKS_NOT_ENABLED); if (!get_kb_item("Host/HP-UX/version")) audit(AUDIT_OS_NOT, "HP-UX"); if (!get_kb_item("Host/HP-UX/swlist")) audit(AUDIT_PACKAGE_LIST_MISSING); if (!hpux_check_ctx(ctx:"11.23 11.31", proc:"ia64")) { exit(0, "The host is not affected since PHSS_38489 applies to a different OS release / architecture."); } patches = make_list("PHSS_38489", "PHSS_38783", "PHSS_39246", "PHSS_39640", "PHSS_39945", "PHSS_40375", "PHSS_40708", "PHSS_41243", "PHSS_41607", "PHSS_41858", "PHSS_42233", "PHSS_43047", "PHSS_43354"); foreach patch (patches) { if (hpux_installed(app:patch)) { exit(0, "The host is not affected because patch "+patch+" is installed."); } } flag = 0; if (hpux_check_patch(app:"OVNNMETCore.OVNNMET-CORE", version:"B.07.50.00")) flag++; if (hpux_check_patch(app:"OVNNMETCore.OVNNMET-IPV6", version:"B.07.50.00")) flag++; if (hpux_check_patch(app:"OVNNMETCore.OVNNMET-PESA", version:"B.07.50.00")) flag++; if (hpux_check_patch(app:"OVNNMgr.OVMIB-CONTRIB", version:"B.07.50.00")) flag++; if (hpux_check_patch(app:"OVNNMgr.OVNNM-RUN", version:"B.07.50.00")) flag++; if (hpux_check_patch(app:"OVNNMgr.OVNNMGR-JPN", version:"B.07.50.00")) flag++; if (hpux_check_patch(app:"OVNNMgr.OVNNMGR-KOR", version:"B.07.50.00")) flag++; if (hpux_check_patch(app:"OVNNMgr.OVNNMGR-SCH", version:"B.07.50.00")) flag++; if (hpux_check_patch(app:"OVNNMgr.OVWWW-JPN", version:"B.07.50.00")) flag++; if (hpux_check_patch(app:"OVNNMgr.OVWWW-KOR", version:"B.07.50.00")) flag++; if (hpux_check_patch(app:"OVNNMgr.OVWWW-SCH", version:"B.07.50.00")) flag++; if (hpux_check_patch(app:"OVNNMgrMan.OVNNM-RUN-MAN", version:"B.07.50.00")) flag++; if (hpux_check_patch(app:"OVNNMgrRtDOC.OVNNM-DOC-REUS", version:"B.07.50.00")) flag++; if (hpux_check_patch(app:"OVNNMgrRtDOC.OVNNM-ENG-DOC", version:"B.07.50.00")) flag++; if (hpux_check_patch(app:"OVPlatform.OVDB-RUN", version:"B.07.50.00")) flag++; if (hpux_check_patch(app:"OVPlatform.OVEVENT-MIN", version:"B.07.50.00")) flag++; if (hpux_check_patch(app:"OVPlatform.OVMIN", version:"B.07.50.00")) flag++; if (hpux_check_patch(app:"OVPlatform.OVWIN", version:"B.07.50.00")) flag++; if (hpux_check_patch(app:"OVPlatform.OVWWW-EVNT", version:"B.07.50.00")) flag++; if (hpux_check_patch(app:"OVPlatform.OVWWW-FW", version:"B.07.50.00")) flag++; if (hpux_check_patch(app:"OVPlatform.OVWWW-SRV", version:"B.07.50.00")) flag++; if (flag) { if (report_verbosity > 0) security_hole(port:0, extra:hpux_report_get()); else security_hole(0); exit(0); } else audit(AUDIT_HOST_NOT, "affected");
NASL family Windows NASL id HP_NNM_SOLIDDB_DOS.NASL description The version of HP OpenView Network Node Manager (NNM) installed on the remote Windows host is affected by multiple vulnerabilities : - The embedded DB service is affected by a denial of service vulnerability that is triggered when it receives a packet with an error code of less than -1. An unauthenticated, remote attacker can exploit this to crash the service. (CVE-2009-3840) - An unspecified flaw exists that allows an unauthenticated, remote attacker to execute arbitrary code. No other details are available. (CVE-2010-2710) This plugin only checks OpenView NNM running on Windows, though other platforms are affected. last seen 2020-06-01 modified 2020-06-02 plugin id 42879 published 2009-11-24 reporter This script is Copyright (C) 2009-2018 Tenable Network Security, Inc. source https://www.tenable.com/plugins/nessus/42879 title HP OpenView Network Node Manager Multiple Vulnerabilities code # # (C) Tenable Network Security, Inc. # include("compat.inc"); if (description) { script_id(42879); script_version("1.14"); script_cvs_date("Date: 2018/11/15 20:50:27"); script_cve_id("CVE-2009-3840", "CVE-2010-2710"); script_bugtraq_id(37046, 42636); script_xref(name:"Secunia", value:"37376"); script_xref(name:"HP", value:"emr_na-c01926980"); script_xref(name:"HP", value:"HPSBMA02477"); script_xref(name:"HP", value:"SSRT090177"); script_xref(name:"EDB-ID", value:"10176"); script_name(english:"HP OpenView Network Node Manager Multiple Vulnerabilities"); script_summary(english:"Does a version check on ovdbrun.exe."); script_set_attribute(attribute:"synopsis", value: "A database service on the remote Windows host is affected by multiple vulnerabilities."); script_set_attribute(attribute:"description", value: "The version of HP OpenView Network Node Manager (NNM) installed on the remote Windows host is affected by multiple vulnerabilities : - The embedded DB service is affected by a denial of service vulnerability that is triggered when it receives a packet with an error code of less than -1. An unauthenticated, remote attacker can exploit this to crash the service. (CVE-2009-3840) - An unspecified flaw exists that allows an unauthenticated, remote attacker to execute arbitrary code. No other details are available. (CVE-2010-2710) This plugin only checks OpenView NNM running on Windows, though other platforms are affected."); script_set_attribute(attribute:"see_also", value:"https://seclists.org/fulldisclosure/2009/Nov/199"); # https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-c01926980 script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?fdf8618d"); script_set_attribute(attribute:"solution", value: "Apply the patch referenced in the vendor advisory."); script_set_cvss_base_vector("CVSS2#AV:N/AC:L/Au:N/C:C/I:C/A:C"); script_set_cvss_temporal_vector("CVSS2#E:POC/RL:OF/RC:C"); script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"); script_set_cvss3_temporal_vector("CVSS:3.0/E:P/RL:O/RC:C"); script_set_attribute(attribute:"exploitability_ease", value:"Exploits are available"); script_set_attribute(attribute:"exploit_available", value:"true"); script_set_attribute(attribute:"vuln_publication_date", value:"2009/11/17"); script_set_attribute(attribute:"patch_publication_date", value:"2009/11/17"); script_set_attribute(attribute:"plugin_publication_date", value:"2009/11/24"); script_set_attribute(attribute:"plugin_type", value:"local"); script_set_attribute(attribute:"cpe", value:"cpe:/a:hp:openview_network_node_manager"); script_end_attributes(); script_category(ACT_GATHER_INFO); script_family(english:"Windows"); script_copyright(english:"This script is Copyright (C) 2009-2018 Tenable Network Security, Inc."); script_dependencies("smb_hotfixes.nasl", "smb_enum_services.nasl"); script_require_ports(139, 445, 2690); script_require_keys("SMB/login", "SMB/password", "SMB/name", "SMB/transport", "SMB/Registry/Enumerated"); exit(0); } include("smb_func.inc"); include("smb_hotfixes.inc"); include("smb_hotfixes_fcheck.inc"); include("audit.inc"); include("misc_func.inc"); svc_name = 'HP OpenView NNM Embedded DB'; svc_running = get_kb_item('SMB/svc/' + svc_name); if (isnull(svc_running)) exit(0, 'The SMB/svc/'+svc_name+' KB item is missing.'); if (svc_running != SERVICE_ACTIVE && report_paranoia < 2) exit(0, 'The ' + svc_name + ' service is not running.'); get_kb_item_or_exit("SMB/Registry/Enumerated"); name = kb_smb_name(); port = kb_smb_transport(); login = kb_smb_login(); pass = kb_smb_password(); domain = kb_smb_domain(); if(! smb_session_init()) audit(AUDIT_FN_FAIL, 'smb_session_init'); rc = NetUseAdd(login:login, password:pass, domain:domain, share:"IPC$"); if (rc != 1) { NetUseDel(); exit(1, "Can't connect to IPC$ share."); } # Connect to remote registry. hklm = RegConnectRegistry(hkey:HKEY_LOCAL_MACHINE); if (isnull(hklm)) { NetUseDel(); exit(1, "Can't connect to remote registry."); } path = NULL; exe = NULL; ovdbrun_key = "SOFTWARE\ovdbrun\ovdbrun\7.50"; ovdbrun_key_h = RegOpenKey(handle:hklm, key:ovdbrun_key, mode:MAXIMUM_ALLOWED); if (!isnull(ovdbrun_key_h)) { item = RegQueryValue(handle:ovdbrun_key_h, item:"exe"); if (!isnull(item)) { path = ereg_replace(pattern:"^(.+)\\[^\\]+$", replace:"\1", string:item[1]); exe = ereg_replace(pattern:"^.+\\([^\\]+)$", replace:"\1", string:item[1]); } RegCloseKey (handle:ovdbrun_key_h); } RegCloseKey(handle:hklm); NetUseDel(); if (isnull(path)) exit(0, "Can't find evidence of ovdbrun in the registry."); if (!is_accessible_share()) exit(1, "is_accessible_share() failed."); if (hotfix_is_vulnerable(file:exe, version:"4.50.0.169", path:path)) { hotfix_security_hole(); hotfix_check_fversion_end(); exit(0); } else { hotfix_check_fversion_end(); audit(AUDIT_HOST_NOT, 'affected'); }
NASL family Databases NASL id SOLIDDB_6_30_37.NASL description The version of IBM solidDB database server installed on the remote host is older than 6.30.0.37 (6.3 Fix Pack 3 / 6.3.37), and hence is affected by a denial of service vulnerability. By sending a specially crafted packet with a negative error code other than -1, it may be possible for an attacker to crash the remote database. last seen 2020-06-01 modified 2020-06-02 plugin id 42877 published 2009-11-24 reporter This script is Copyright (C) 2009-2018 Tenable Network Security, Inc. source https://www.tenable.com/plugins/nessus/42877 title IBM solidDB < 6.30.0.37 Invalid Error Code DoS code # # (C) Tenable Network Security, Inc. # include("compat.inc"); if (description) { script_id(42877); script_version("1.9"); script_cvs_date("Date: 2018/11/15 20:50:21"); script_cve_id("CVE-2009-3840"); script_bugtraq_id(37053); script_xref(name:"Secunia", value:"37380"); script_name(english:"IBM solidDB < 6.30.0.37 Invalid Error Code DoS"); script_summary(english:"Checks version of solid.exe"); script_set_attribute(attribute:"synopsis", value: "The remote database server is affected by a denial of service vulnerability."); script_set_attribute(attribute:"description", value: "The version of IBM solidDB database server installed on the remote host is older than 6.30.0.37 (6.3 Fix Pack 3 / 6.3.37), and hence is affected by a denial of service vulnerability. By sending a specially crafted packet with a negative error code other than -1, it may be possible for an attacker to crash the remote database."); script_set_attribute(attribute:"see_also", value:"http://www.coresecurity.com/content/ibm-soliddb-errorcode-dos"); script_set_attribute(attribute:"see_also", value:"https://seclists.org/fulldisclosure/2009/Nov/205"); script_set_attribute(attribute:"see_also", value:"http://www-01.ibm.com/support/docview.wss?rs=0&q1=solidb&uid=swg24024510"); script_set_attribute(attribute:"solution", value:"Upgrade to IBM solidDB 6.30.0.37 (6.3 Fix Pack 3 / 6.3.37)."); script_set_cvss_base_vector("CVSS2#AV:N/AC:L/Au:N/C:N/I:N/A:P"); script_set_cvss_temporal_vector("CVSS2#E:POC/RL:OF/RC:C"); script_set_attribute(attribute:"exploitability_ease", value:"Exploits are available"); script_set_attribute(attribute:"exploit_available", value:"true"); script_set_attribute(attribute:"vuln_publication_date", value:"2009/11/18"); script_set_attribute(attribute:"patch_publication_date", value:"2009/11/17"); script_set_attribute(attribute:"plugin_publication_date", value:"2009/11/24"); script_set_attribute(attribute:"plugin_type", value:"local"); script_set_attribute(attribute:"cpe", value:"cpe:/a:ibm:soliddb"); script_end_attributes(); script_category(ACT_GATHER_INFO); script_family(english:"Databases"); script_copyright(english:"This script is Copyright (C) 2009-2018 Tenable Network Security, Inc."); script_dependencies("smb_hotfixes.nasl","soliddb_detect.nasl"); script_require_keys("SMB/Registry/Enumerated"); script_require_ports(139, 445, "Services/soliddb"); exit(0); } include("smb_func.inc"); include("audit.inc"); include("smb_hotfixes.inc"); if(report_paranoia < 2) if(!get_kb_item("Services/soliddb")) exit(0, "The 'Services/soliddb' KB item is missing."); if (!get_kb_item("SMB/Registry/Enumerated")) exit(1,"The 'SMB/Registry/Enumerated' KB item is missing."); # Get the install path name = kb_smb_name(); port = kb_smb_transport(); login = kb_smb_login(); pass = kb_smb_password(); domain = kb_smb_domain(); if(! smb_session_init()) audit(AUDIT_FN_FAIL, 'smb_session_init'); rc = NetUseAdd(login:login, password:pass, domain:domain, share:"IPC$"); if (rc != 1) { NetUseDel(); exit(1,"Can't connect to IPC$ share."); } hklm = RegConnectRegistry(hkey:HKEY_LOCAL_MACHINE); if (isnull(hklm)) { NetUseDel(); exit(1,"Can't connect to remote registry."); } path = NULL; key = "SOFTWARE\Microsoft\Windows\CurrentVersion\App Paths\solid.exe"; key_h = RegOpenKey(handle:hklm, key:key, mode:MAXIMUM_ALLOWED); if (!isnull(key_h)) { # If SolidDB is installed... item = RegQueryValue(handle:key_h, item:"Path"); if (!isnull(item)) path = item[1]; RegCloseKey(handle:key_h); } if (isnull(path)) { # Figure out where the installer recorded information about it. list = get_kb_list("SMB/Registry/HKLM/SOFTWARE/Microsoft/Windows/CurrentVersion/Uninstall/*/DisplayName"); if (isnull(list)) exit(1,"Could not get Uninstall KB."); installstring = NULL; foreach name (keys(list)) { prod = list[name]; if (prod && "solidDB " >< prod) { installstring = ereg_replace(pattern:"^SMB\/Registry\/HKLM\/(SOFTWARE\/Microsoft\/Windows\/CurrentVersion\/Uninstall\/.+)\/DisplayName$", replace:"\1", string:name); installstring = str_replace(find:"/", replace:"\", string:installstring); break; } } if(!isnull(installstring)) { key_h = RegOpenKey(handle:hklm, key:installstring, mode:MAXIMUM_ALLOWED); if (!isnull(key_h)) { # If SolidDB is installed... item = RegQueryValue(handle:key_h, item:"InstallLocation"); if (!isnull(item)) path = item[1] + "\bin"; RegCloseKey(handle:key_h); } } } RegCloseKey(handle:hklm); if(isnull(path)) { NetUseDel(); exit(1,"Could not get path."); } share = ereg_replace(pattern:"^([A-Za-z]):.*", replace:"\1$", string:path); exe = ereg_replace(pattern:"^[A-Za-z]:(.*)", replace:"\1\solid.exe", string:path); file = path + "\solid.exe"; NetUseDel(close:FALSE); rc = NetUseAdd(login:login, password:pass, domain:domain, share:share); if (rc != 1) { NetUseDel(); exit(1, "Can't connect to "+ share + " share."); } fh = CreateFile(file:exe, desired_access:GENERIC_READ, file_attributes:FILE_ATTRIBUTE_NORMAL, share_mode:FILE_SHARE_READ, create_disposition:OPEN_EXISTING); ver = NULL; if (!isnull(fh)) { ver = GetFileVersion(handle:fh); CloseFile(handle:fh); } NetUseDel(); # Check the version number. if (!isnull(ver)) { fixed_version = "6.30.0.37"; fix = split(fixed_version, sep:'.', keep:FALSE); for (i=0; i<max_index(fix); i++) fix[i] = int(fix[i]); for (i=0; i<max_index(ver); i++) if ((ver[i] < fix[i])) { if (report_verbosity > 0) { version = ver[0] + "." + ver[1] + "." + ver[2] + "." + ver[3]; report = '\n' + "File : " + file + '\n' + "Installed version : " + version + '\n' + "Fixed version : " + fixed_version + '\n'; security_warning(port:port, extra:report); } else security_warning(port); exit(0); } else if (ver[i] > fix[i]) break; exit(0, "solid.exe version "+version+" is installed and not vulnerable."); } else exit(1, "Can't get file version of 'solid.exe'.");
Packetstorm
data source https://packetstormsecurity.com/files/download/82767/CORE-2009-0814.txt id PACKETSTORM:82767 last seen 2016-12-05 published 2009-11-18 reporter Core Security Technologies source https://packetstormsecurity.com/files/82767/Core-Security-Technologies-Advisory-2009.0814.html title Core Security Technologies Advisory 2009.0814 data source https://packetstormsecurity.com/files/download/82790/CORE-2009-1027.txt id PACKETSTORM:82790 last seen 2016-12-05 published 2009-11-19 reporter Core Security Technologies source https://packetstormsecurity.com/files/82790/Core-Security-Technologies-Advisory-2009.1027.html title Core Security Technologies Advisory 2009.1027
Seebug
bulletinFamily exploit description No description provided by source. id SSV:18462 last seen 2017-11-19 modified 2009-11-18 published 2009-11-18 reporter Root source https://www.seebug.org/vuldb/ssvid-18462 title IBM SolidDB invalid error code vulnerability bulletinFamily exploit description No description provided by source. id SSV:18272 last seen 2017-11-19 modified 2009-11-17 published 2009-11-17 reporter Root source https://www.seebug.org/vuldb/ssvid-18272 title HP Openview NNM 7.53 Invalid DB Error Code Vulnerability bulletinFamily exploit description BUGTRAQ ID: 37053 CVE ID: CVE-2009-3840 IBM solidDB是可实现电信级性能的关系数据库。 IBM SolidDB包含有一个内嵌式的数据库服务组件(solid.exe),该服务默认启用,在2315/tcp端口上接受远程连接。在从网络接收到报文时,服务会基于报文中所指定的出错代码编号确定并显示出错代码字符串。如果攻击者发送了带有无效出错代码编号的特制报文,就可以触发异常,强制终止服务。以下是有漏洞部分的代码段: /----- 0061611F 0FB65424 02 MOVZX EDX,BYTE PTR SS:[ESP+2] 00616124 0FBF4C24 03 MOVSX ECX,WORD PTR SS:[ESP+3] 00616129 83F9 FF CMP ECX,-1 0061612C 0FBF4424 05 MOVSX EAX,WORD PTR SS:[ESP+5] 00616131 8956 10 MOV DWORD PTR DS:[ESI+10],EDX 00616134 8B5424 07 MOV EDX,DWORD PTR SS:[ESP+7] 00616138 894E 14 MOV DWORD PTR DS:[ESI+14],ECX 0061613B 8946 18 MOV DWORD PTR DS:[ESI+18],EAX 0061613E 8956 0C MOV DWORD PTR DS:[ESI+C],EDX 00616141 7D 09 JGE SHORT solid.0061614C 00616143 83F8 FF CMP EAX,-1 00616146 7D 04 JGE SHORT solid.0061614C 00616148 3BC8 CMP ECX,EAX 0061614A 74 05 JE SHORT solid.00616151 0061614C B8 01000000 MOV EAX,1 00616151 83C4 0C ADD ESP,0C 00616154 C3 RETN - -----/ 上述代码基于报文中的Error Code字段检查出错情况,如果Error Code值小于或等于-1就会处理出错情况,在这种情况下会向用户显示包含有相关描述性的出错字符串的MessageBox。但通过创建Error Code字段值为非-1的负数值的报文,查询相应出错字符串就会失败,触发不可恢复的错误,终止服务器进程。 IBM solidDB 6.30.0.33 IBM solidDB 6.30.0.29 厂商补丁: IBM --- 目前厂商已经发布了升级补丁以修复这个安全问题,请到厂商的主页下载: http://www-01.ibm.com/support/docview.wss?rs=0&q1=solidb&uid=swg24024510 id SSV:12666 last seen 2017-11-19 modified 2009-11-19 published 2009-11-19 reporter Root source https://www.seebug.org/vuldb/ssvid-12666 title IBM SolidDB solid.exe远程拒绝服务漏洞